Integrated backscatter and digital acquisition during myocardial contrast echocardiography: is there an advantage over conventional echocardiography for intracoronary injections?

S Ismail1, A R Jayaweera, D M Skyba, J Sklenar, N C Goodman, S Kaul.   

Abstract

This study was designed to answer the question of whether, despite their theoretic superiority, integrated backscatter imaging (IBS) and digital data acquisition (DA) offer any advantage over conventional echocardiography (CE) during quantitative myocardial contrast echocardiography. In vitro experiments were performed (1) to determine the microbubble concentration versus videointensity relationships for CE and IBS and (2) to define the relationship between flow through and microbubble transit rates for CE and IBS. These data were stored on videotape. In vivo experiments were performed whereby microbubbles were injected into the left anterior descending artery at different flow rates in 14 dogs and IBS and CE data were stored both in digital format and on videotape. Although the level of compression did not affect the microbubble concentration versus videointensity plots during IBS compared with CE, in practical terms the mean transit rate, peak intensity, and area under the curve were not affected by the level of compression for both forms of imaging as long as the postprocessing used for CE imaging was linear and the microbubble dose was small. In addition, although DA resulted in higher peak intensity and area under the curve compared with storage on videotape because of its broader dynamic range, the correlation between these measurements was excellent with both forms of image storage. We conclude that, although differences exist between CE and IBS and between Da and analog acquisition, these differences do not significantly affect the derivation of parameters from time-intensity plots during myocardial contrast echocardiography when contrast material is injected into a coronary artery.

Entities:  

Mesh:

Year:  1995        PMID: 7546781     DOI: 10.1016/s0894-7317(05)80332-3

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

Review 1.  [New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].

Authors:  M Haude; G Caspari; D Baumgart; P Spiller; G Heusch; R Erbel
Journal:  Herz       Date:  1997-04       Impact factor: 1.443

2.  Myocardial blood volume and the amount of viable myocardium early after mechanical reperfusion of acute myocardial infarction: prospective study using venous contrast echocardiography.

Authors:  P Andrássy; M Zielinska; R Busch; A Schömig; C Firschke
Journal:  Heart       Date:  2002-04       Impact factor: 5.994

3.  Effect of pressure on intracardiac backscatter from microbubbles.

Authors:  Y Deng; C Li; Q Chang
Journal:  J Tongji Med Univ       Date:  2001
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.