Literature DB >> 12538068

Evaluation of trajectories and contact pressures for the straight nucleus cochlear implant electrode array - a two-dimensional application of finite element analysis.

B K Chen1, G M Clark, R Jones.   

Abstract

A two-dimensional (2D) finite element analysis has been used in this study to model the insertion of the Nucleus electrode array with different stiffness properties in order to evaluate the propensity of damage by visualizing the predicted trajectories and by comparing the buckling stresses and the contact pressures at the tip (and its distribution along the length) of the electrode array. Previous temporal bone studies have shown that damage during insertion of an electrode array around the basal turn of the cochlear spiral could be related to the design and the stiffness properties of the electrode array. However, it is difficult to evaluate different designs of electrode arrays purely by experimental methods as the experimental conditions and their results are difficult to reproduce. Three electrode arrays with different mechanical properties, i.e. uniform stiffness, graded stiffness, and a soft tip have been modelled. Buckling stress and contact pressure at the tip of the electrode array were found to be highest for the arrays with uniform stiffness. The contact pressures at the tip of the electrode array appeared strongly influenced by the stiffness profile and were optimal for graded stiffness. The results indicate the importance of the electrode array design and stiffness properties in minimizing trauma. However, there are a number of limitations in the present 2D evaluation which will require further analysis using a three-dimensional model to obtain definitive results.

Entities:  

Mesh:

Year:  2003        PMID: 12538068     DOI: 10.1016/s1350-4533(02)00150-9

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  8 in total

1.  Determination of the curling behavior of a preformed cochlear implant electrode array.

Authors:  Thomas S Rau; Omid Majdani; Andreas Hussong; Thomas Lenarz; Martin Leinung
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-07-28       Impact factor: 2.924

2.  Anatomy of the round window and hook region of the cochlea with implications for cochlear implantation and other endocochlear surgical procedures.

Authors:  Peter M M C Li; Haobing Wang; Clarinda Northrop; Saumil N Merchant; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2007-08       Impact factor: 2.311

Review 3.  Soft cochlear implantation: rationale for the surgical approach.

Authors:  David R Friedland; Christina Runge-Samuelson
Journal:  Trends Amplif       Date:  2009-06

4.  Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion.

Authors:  Stephen J Rebscher; Alexander Hetherington; Ben Bonham; Peter Wardrop; David Whinney; Patricia A Leake
Journal:  J Rehabil Res Dev       Date:  2008

Review 5.  Cochlear implants: system design, integration, and evaluation.

Authors:  Fan-Gang Zeng; Stephen Rebscher; William Harrison; Xiaoan Sun; Haihong Feng
Journal:  IEEE Rev Biomed Eng       Date:  2008-11-05

6.  Three-dimensional histological specimen preparation for accurate imaging and spatial reconstruction of the middle and inner ear.

Authors:  Thomas S Rau; Waldemar Würfel; Thomas Lenarz; Omid Majdani
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-04-30       Impact factor: 2.924

7.  A clinically oriented introduction and review on finite element models of the human cochlea.

Authors:  Dimitrios Kikidis; Athanasios Bibas
Journal:  Biomed Res Int       Date:  2014-11-04       Impact factor: 3.411

Review 8.  Recent Advances in Cochlear Implant Electrode Array Design Parameters.

Authors:  Yavuz Nuri Ertas; Derya Ozpolat; Saime Nur Karasu; Nureddin Ashammakhi
Journal:  Micromachines (Basel)       Date:  2022-07-08       Impact factor: 3.523

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.