Literature DB >> 12515755

Magnetic resonance image-guided transcatheter closure of atrial septal defects.

Carsten Rickers1, Michael Jerosch-Herold, Xudong Hu, Naveen Murthy, Xiaoen Wang, Huafu Kong, Ravi Teja Seethamraju, Jochen Weil, Norbert M Wilke.   

Abstract

BACKGROUND: Recent developments in cardiac MRI have extended the potential spectrum of diagnostic and interventional applications. The purpose of this study was to test the ability of MRI to perform transcatheter closures of secundum type atrial septal defects (ASD) and to assess ASD size and changes in right cardiac chamber volumes in the same investigation. METHODS AND
RESULTS: In 7 domestic swine (body weight, 38+/-13 kg), an ASD (Q(p):Q(s)=1.7+/-0.2) was created percutaneously by balloon dilation of the fossa ovalis. The ASD was imaged and sized by both conventional radiography and MRI. High-resolution MRI of the ASD diameters correlated well with postmortem examination (r=0.97). Under real-time MR fluoroscopy, the introducer sheath was tracked toward the left atrium with the use of novel miniature MR guide wires. The defect was then closed with an Amplatzer Septal Occluder. In all animals, it was possible to track and interactively control the position of the guide wire within the vessels and the heart, including the successful deployment of the Amplatzer Septal Occluder. Right atrial and ventricular volumes were calculated before and after the intervention by using cine-MRI. Both volumes were found to be significantly reduced after ASD closure (P<0.005).
CONCLUSIONS: These in vivo studies demonstrate that catheter tracking and ASD device closure can be performed under real-time MRI guidance with the use of intravascular antenna guide wires. High-resolution imaging allows accurate determination of ASD size before the intervention, and immediate treatment effects such as changes in right cardiac volumes can also be measured.

Entities:  

Mesh:

Year:  2003        PMID: 12515755     DOI: 10.1161/01.cir.0000039343.95540.cf

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  28 in total

Review 1.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

2.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

Review 3.  Advances in interventional cardiovascular MRI.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

4.  Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine.

Authors:  Venkatesh K Raman; Parag V Karmarkar; Michael A Guttman; Alexander J Dick; Dana C Peters; Cengizhan Ozturk; Breno S S Pessanha; Richard B Thompson; Amish N Raval; Ranil DeSilva; Ronnier J Aviles; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  J Am Coll Cardiol       Date:  2005-06-21       Impact factor: 24.094

5.  Real-time MRI guided atrial septal puncture and balloon septostomy in swine.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Ranil Desilva; Ronnier J Aviles; Victor J Wright; William H Schenke; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2006-04       Impact factor: 2.692

6.  Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2006-02-20       Impact factor: 29.690

Review 7.  Interventional cardiovascular magnetic resonance imaging.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Trends Cardiovasc Med       Date:  2007-08       Impact factor: 6.677

8.  Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System.

Authors:  Prasheel V Lillaney; Jeffrey K Yang; Aaron D Losey; Alastair J Martin; Daniel L Cooke; Bradford R H Thorne; David C Barry; Andrew Chu; Carol Stillson; Loi Do; Ronald L Arenson; Maythem Saeed; Mark W Wilson; Steven W Hetts
Journal:  Radiology       Date:  2016-03-28       Impact factor: 11.105

Review 9.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

10.  Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in Swine.

Authors:  Alexander J Dick; Michael A Guttman; Venkatesh K Raman; Dana C Peters; Breno S S Pessanha; Jonathan M Hill; Scott Smith; Greig Scott; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2003-12-01       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.