Literature DB >> 12512783

The reproducibility of cephalometric measurements: a comparison of analogue and digital methods.

E M Ongkosuwito1, C Katsaros, M A van 't Hof, J C Bodegom, A M Kuijpers-Jagtman.   

Abstract

The aim of this study was to compare the reproducibility of longitudinal cephalometric measurements between analogue and digital methods using two different resolutions. Cephalometric radiographs of 20 patients were selected at the start (T1) and end (T2) of treatment: 24 cephalometric variables were calculated at T1 and T2, and their increments (T2 - T1) were also evaluated. All measurements were performed twice by two observers. Quality of methods [analogue, digital: 300 and 600 dots per inch (DPI) resolution] was evaluated by comparing the reliability coefficients and the total error between the digital and analogue methods. The inter-observer agreement was good. The 300 DPI was comparable to the analogue method. The reproducibility for the variables was comparable, but mandibular incisor increments tended to show better results with the 300 DPI method, whereas skeletal jaw relationship increments were not reliable with either method. Maxillary incisor increments, however, were reliable with both methods. The 300 and 600 DPI resolutions were found to be comparable. Scanning of cephalometric radiographs at a resolution of 300 DPI is sufficient for clinical purposes and comparable to analogue cephalometrics. However, all methods were found to be poor in assessing skeletal jaw relationships longitudinally.

Entities:  

Mesh:

Year:  2002        PMID: 12512783     DOI: 10.1093/ejo/24.6.655

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  12 in total

1.  The reliability and reproducibility of cephalometric measurements: a comparison of conventional and digital methods.

Authors:  S F Albarakati; K S Kula; A A Ghoneima
Journal:  Dentomaxillofac Radiol       Date:  2012-01       Impact factor: 2.419

2.  The relationship between craniofacial development and hypodontia in patients with Down syndrome.

Authors:  D J F van Marrewijk; M A E van Stiphout; W Reuland-Bosma; E M Bronkhorst; E M Ongkosuwito
Journal:  Eur J Orthod       Date:  2015-08-14       Impact factor: 3.075

3.  The reliability and reproducibility of an Android cephalometric smartphone application in comparison with the conventional method.

Authors:  Obada M Zamrik; Haluk İşeri
Journal:  Angle Orthod       Date:  2021-03-01       Impact factor: 2.079

4.  Assessing the Reliability of Digitalized Cephalometric Analysis in Comparison with Manual Cephalometric Analysis.

Authors:  Mohammed Umar Farooq; Mohd Asadullah Khan; Shahid Imran; Ayesha Sameera; Arshad Qureshi; Syed Afroz Ahmed; Sujan Kumar; Mohd Aziz Ur Rahman
Journal:  J Clin Diagn Res       Date:  2016-10-01

5.  Coordinating bracket torque and incisor inclination : Part 3: Validity of bracket torque values in achieving norm inclinations.

Authors:  Bernd Zimmer; Hiba Sino
Journal:  J Orofac Orthop       Date:  2018-03-19       Impact factor: 1.938

6.  Coordinating bracket torque and incisor inclination : Part 2: Reproducibility and statistical measures of the torque coordination angle (TCA).

Authors:  H Sino; B Zimmer; I Schelper; S Schenk-Kazan; F Streibelt
Journal:  J Orofac Orthop       Date:  2018-03-09       Impact factor: 1.938

7.  Comparative Evaluation of Conventional and OnyxCeph™ Dental Software Measurements on Cephalometric Radiography.

Authors:  Elif İzgi; Filiz Namdar Pekiner
Journal:  Turk J Orthod       Date:  2019-06-01

8.  Reproducibility of measurements in tablet-assisted, PC-aided, and manual cephalometric analysis.

Authors:  Cecilia Goracci; Marco Ferrari
Journal:  Angle Orthod       Date:  2013-10-25       Impact factor: 2.079

9.  Ceph-X: development and evaluation of 2D cephalometric system.

Authors:  Mogeeb Ahmed Ahmed Mosleh; Mohd Sapiyan Baba; Sorayya Malek; Rasheed A Almaktari
Journal:  BMC Bioinformatics       Date:  2016-12-22       Impact factor: 3.169

10.  Cone-beam computed tomography for assessment of palatal displaced canine position: a methodological study.

Authors:  Julia Naoumova; Heidrun Kjellberg; Reet Palm
Journal:  Angle Orthod       Date:  2013-10-25       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.