Literature DB >> 16872072

Measurement of the internal diameter of plastic tubes from projection MR images using a model-based least-squares fit approach.

Yang-Sheng Tzeng1, Joey Mansour, Zachary Handler, Jessica Gereige, Niral Shah, Xin Zhou, Mitchell Albert.   

Abstract

Hyperpolarized (HP) 3He MRI is an emerging tool in the diagnosis and evaluation of pulmonary diseases involving bronchoconstriction, such as asthma. Previously, airway diameters from dynamic HP 3He MR images of the lung were assessed manually and subjectively, and were thus prone to uncertainties associated with human error and partial volume effects. A model-based algorithm capable of fully utilizing pixel intensity profile information and attaining subpixel resolution has been developed to measure surrogate airway diameters from HP 3He MR static projection images of plastic tubes. This goal was achieved by fitting ideal pixel intensity profiles for various diameter (6.4 to 19.1 mm) circular tubes to actual pixel intensity data. A phantom was constructed from plastic tubes of various diameters connected in series and filled with water mixed with contrast agent. Projection MR images were then taken of the phantom. The favorable performance of the model-based algorithm compared to manual assessment demonstrates the viability of our approach. The manual and algorithm approaches yielded diameter measurements that generally stayed within 1 x the pixel dimension. However, inconsistency of the manual approach can be observed from the larger standard deviations of its measured values. The method was then extended to HP 3He MRI, producing encouraging results at tube diameters characteristic of airways beyond the second generation, thereby justifying their application to lung airway imaging and measurement. Potential obstacles when measuring airway diameters using this method are discussed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16872072      PMCID: PMC2934785          DOI: 10.1118/1.2194427

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  How does airway inflammation modulate asthmatic airway constriction? An antigen challenge study.

Authors:  A C Henderson; E P Ingenito; H Atileh; E Israel; B Suki; K R Lutchen
Journal:  J Appl Physiol (1985)       Date:  2003-04-18

2.  Dynamic 3He imaging for quantification of regional lung ventilation parameters.

Authors:  David Dupuich; Yves Berthezène; Pierre-Louis Clouet; Vasile Stupar; Emmanuelle Canet; Yannick Crémillieux
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

3.  Imaging the lungs in asthmatic patients by using hyperpolarized helium-3 magnetic resonance: assessment of response to methacholine and exercise challenge.

Authors:  Saba Samee; Talissa Altes; Patrick Powers; Eduard E de Lange; Jack Knight-Scott; Gary Rakes; John P Mugler; Jonathan M Ciambotti; Bennet A Alford; James R Brookeman; Thomas A E Platts-Mills
Journal:  J Allergy Clin Immunol       Date:  2003-06       Impact factor: 10.793

4.  Evaluation of airway wall thickness and air trapping by HRCT in asymptomatic asthma.

Authors:  H Gono; K Fujimoto; S Kawakami; K Kubo
Journal:  Eur Respir J       Date:  2003-12       Impact factor: 16.671

5.  Airway narrowing in excised canine lungs measured by high-resolution computed tomography.

Authors:  A E McNamara; N L Müller; M Okazawa; J Arntorp; B R Wiggs; P D Paré
Journal:  J Appl Physiol (1985)       Date:  1992-07

6.  Morphology of the bronchial tree in man.

Authors:  K Horsfield; G Cumming
Journal:  J Appl Physiol       Date:  1968-03       Impact factor: 3.531

7.  Measurement of signal intensities in the presence of noise in MR images.

Authors:  R M Henkelman
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

8.  Distal airways in humans: dynamic hyperpolarized 3He MR imaging--feasibility.

Authors:  Angela C Tooker; Kwan Soo Hong; Erin L McKinstry; Philip Costello; Ferenc A Jolesz; Mitchell S Albert
Journal:  Radiology       Date:  2003-03-27       Impact factor: 11.105

9.  Assessment of methacholine-induced airway constriction by ultrafast high-resolution computed tomography.

Authors:  I Amirav; S S Kramer; M M Grunstein; E A Hoffman
Journal:  J Appl Physiol (1985)       Date:  1993-11

10.  Dynamic radial projection MRI of inhaled hyperpolarized 3He gas.

Authors:  Jim M Wild; Martyn N J Paley; Larry Kasuboski; Andrew Swift; Stan Fichele; Neil Woodhouse; Paul D Griffiths; Edwin J R van Beek
Journal:  Magn Reson Med       Date:  2003-06       Impact factor: 4.668

View more
  3 in total

1.  Comparison of airway diameter measurements from an anthropomorphic airway tree phantom using hyperpolarized 3He MRI and high-resolution computed tomography.

Authors:  Yang-Sheng Tzeng; Eric Hoffman; Janice Cook-Granroth; Rie Maurer; Niral Shah; Joey Mansour; Juerg Tschirren; Mitchell Albert
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

2.  Measurement of lung airways in three dimensions using hyperpolarized helium-3 MRI.

Authors:  Eric T Peterson; Jionghan Dai; James H Holmes; Sean B Fain
Journal:  Phys Med Biol       Date:  2011-04-27       Impact factor: 3.609

3.  Investigation of hyperpolarized 3He magnetic resonance imaging utility in examining human airway diameter behavior in asthma through comparison with high-resolution computed tomography.

Authors:  Yang-Sheng Tzeng; Eric Hoffman; Janice Cook-Granroth; Jessica Gereige; Joey Mansour; George Washko; Michael Cho; Evan Stepp; Kenneth Lutchen; Mitchell Albert
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.