Literature DB >> 12493510

Sorin Bicarbon bileaflet valve: a 10-year experience.

J B Borman1, C De Riberolles.   

Abstract

OBJECTIVE: To present a large 10 year experience of a collaborative evaluation of the Sorin Bicarbon (SB) mechanical prosthesis carried out in 14 centers in eight Western European countries.
METHODS: Between 4/90 and 12/96, 2078 SB valves were implanted in 1875 patients aged 4-84 years (mean 58), 1108 males and 767 females. The valves inserted were 1026 aortic valve replacement (AVR), 656 mitral valve replacement (MVR) and 203 double valve replacement (DVR), additional procedures performed in 467 patients (282 coronary artery bypass grafting).
RESULTS: Early mortality was 97 (5%), overall survival at 8 years was 71.8% AVR, 69.4% MVR, 81.4% DVR. Total late valve-related deaths were 55; overall freedom from valve-related death at 8 years was 95%. New York Heart Association (NYHA) status after surgery: 78% improved and 17% unchanged. Twenty-two valve thrombosis were observed, one fatal; overall freedom from thrombosis at 8 years was 98.5%. Embolism occurred in 95 patients, 77 cerebral events (16 deaths), overall freedom from embolism was 90.7% at 8 years. Six hemolytic events and 26 non-structural dysfunction (all periprosthetic leaks) were reported. Major bleeding occurred in 66, with mortality rate of 32% mainly when intracerebral. Overall freedom from bleeding was 90.8% at 8 years. Endocarditis occurred in 31 patients, 29% were fatal; overall freedom from endocarditis was 97.8% at 8 years. Reoperation was performed in 49 cases--periprosthetic leak 20, infective endocarditis 14, thrombosed valve 13 (and non-valve related-2). Mortality (early and late) occurred in three reoperated patients.
CONCLUSIONS: This is a durable and effective mechanical valve substitute with low morbidity and mortality and good functional results.

Entities:  

Mesh:

Year:  2003        PMID: 12493510     DOI: 10.1016/s1010-7940(02)00658-9

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  7 in total

1.  Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart.

Authors:  Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

2.  Clinical experience with the Bicarbon heart valve prosthesis.

Authors:  Yoshio Misawa; Tsutomu Saito; Hiroaki Konishi; Shin-Ichi Oki; Yuichiro Kaminishi; Yasuhito Sakano; Hideki Morita; Kei Aizawa
Journal:  J Cardiothorac Surg       Date:  2007-01-25       Impact factor: 1.637

3.  10-year results of On-X bileaflet mechanical heart valve in the aortic position: low target INR regimen in Japanese.

Authors:  Hideki Teshima; Masahiko Ikebuchi; Yosuke Miyamoto; Ryuta Tai; Toshikazu Sano; Yusuke Kinugasa; Hiroyuki Irie
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-04-19

4.  Experience with the Edwards MIRA mechanical bileaflet valve in the aortic and mitral positions.

Authors:  Arzum Kale; Ulku Yildiz; Benhur Can; Ozer Kandemir; Hilmi Tokmakoglu; Tevfik Tezcaner; Yaman Zorlutuna
Journal:  Tex Heart Inst J       Date:  2006

Review 5.  Valve-related complications after mechanical heart valve implantation.

Authors:  Yoshio Misawa
Journal:  Surg Today       Date:  2014-12-18       Impact factor: 2.549

6.  Fifteen-year experience with the Bicarbon heart valve prosthesis in a single center.

Authors:  Yoshio Misawa; Arata Muraoka; Shin-ichi Ohki; Kei Aizawa; Koji Kawahito; Tsutomu Saito; Hirotaka Sato; Ippei Takazawa; Soki Kurumisawa; Hirohiko Akutsu; Akira Sugaya
Journal:  J Cardiothorac Surg       Date:  2015-06-28       Impact factor: 1.637

7.  Nineteen Years of Single Institute Experiences with Sorin Bicarbon Prosthesis.

Authors:  Hung Dung Van
Journal:  Ann Thorac Cardiovasc Surg       Date:  2019-03-12       Impact factor: 1.520

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.