Literature DB >> 12486512

Monitoring accommodative ciliary muscle function using three-dimensional ultrasound.

Oliver Stachs1, Heiner Martin, Alexander Kirchhoff, Joachim Stave, Thom Terwee, Rudolf Guthoff.   

Abstract

BACKGROUND: Our objective was to develop a three-dimensional high-resolution ultrasonic imaging technique to be utilized for in-vivo characterization of the ciliary body and the posterior iris. The benefit of this imaging in enhancing the quantification of the configurational changes in the ciliary body during accommodation is demonstrated.
METHODS: Sequential ultrasound biomicroscopic images of the ciliary body region were obtained with a computer-controlled scanning device designed for use with a standard ultrasound biomicroscope for 3D imaging. Custom-made software allows online data collection, data analysis and 3D reconstruction in conjunction with commercially available VoxelView software.
RESULTS: The three-dimensional presentation allows a close approximation of the ciliary muscle inside the ciliary body in vivo. We are able to distinguish and to analyze the changes in the muscle contour in different accommodation states. During accommodation a shift in the ciliary muscle center of gravity in a range of 0.04-0.26 mm (mean 0.13+/-0.06 mm) in the direction of the lens equator, with an interindividual variation and a small decrease with age, was observed.
CONCLUSIONS: High-resolution ultrasound is a well established technique for in-vivo investigation of the anterior segment. Three-dimensional ultrasound biomicroscopy allows an assessment of the individual ciliary muscle activity in consideration of the ciliary processes. In combination with a contour analysis tool we improved the muscle contour determination during different accommodation states. The investigation showed an activity of the ciliary muscle in young volunteers as well as those of presbyopic age.

Mesh:

Year:  2002        PMID: 12486512     DOI: 10.1007/s00417-002-0551-2

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  25 in total

Review 1.  Accommodating intraocular lenses: a critical review of present and future concepts.

Authors:  R Menapace; O Findl; K Kriechbaum; Ch Leydolt-Koeppl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-08-30       Impact factor: 3.117

2.  Three-dimensional ultrasound biomicroscopy, environmental and conventional scanning electron microscopy investigations of the human zonula ciliaris for numerical modelling of accommodation.

Authors:  Oliver Stachs; Heiner Martin; Detlef Behrend; Klaus-Peter Schmitz; Rudolf Guthoff
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-10-05       Impact factor: 3.117

3.  [Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].

Authors:  O Stachs; H Schneider; J Stave; R Beck; R F Guthoff
Journal:  Ophthalmologe       Date:  2005-03       Impact factor: 1.059

4.  Comment on the publication "Three-dimensional ultrasound, biomicroscopy environmental and conventional scanning electron microscopy investigations of the human zonula ciliaris for numerical modelling of accommodation" by O. Stachs et al.

Authors:  Ronald A Schachar; Ali Abolmaali; Farhad Kamangar
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-03-08       Impact factor: 3.117

5.  Ciliary muscle thickness profiles derived from optical coherence tomography images.

Authors:  Sandra Wagner; Eberhart Zrenner; Torsten Strasser
Journal:  Biomed Opt Express       Date:  2018-10-01       Impact factor: 3.732

6.  Quantification of the ciliary muscle and crystalline lens interaction during accommodation with synchronous OCT imaging.

Authors:  Marco Ruggeri; Carolina de Freitas; Siobhan Williams; Victor M Hernandez; Florence Cabot; Nilufer Yesilirmak; Karam Alawa; Yu-Cherng Chang; Sonia H Yoo; Giovanni Gregori; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2016-03-17       Impact factor: 3.732

Review 7.  [Presbyopia correction using intraocular lenses].

Authors:  M P Holzer; T M Rabsilber; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

8.  Variability of manual ciliary muscle segmentation in optical coherence tomography images.

Authors:  Yu-Cherng Chang; Keke Liu; Florence Cabot; Sonia H Yoo; Marco Ruggeri; Arthur Ho; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2018-01-25       Impact factor: 3.732

9.  Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens.

Authors:  Hanka Schneider; Oliver Stachs; Katja Göbel; Rudolf Guthoff
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-17       Impact factor: 3.117

10.  Measuring changes in ciliary muscle thickness with accommodation in young adults.

Authors:  Laura Ashley Lossing; Loraine T Sinnott; Chiu-Yen Kao; Kathryn Richdale; Melissa D Bailey
Journal:  Optom Vis Sci       Date:  2012-05       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.