Literature DB >> 12475859

The influence of pulmonary staple line reinforcement on air leaks.

Kevin D Murray1, Chih-Hsiang Ho, Jiun-Yi James Hsia, Alex G Little.   

Abstract

OBJECTIVES: Although uncommon, prolonged postoperative air leaks are a troublesome complication of lung surgery. This study was performed to determine if buttressing pulmonary staple lines would reduce air leakage at varying airway pressures, and if there was a difference between buttressing materials.
METHODS: Using cadaver lungs, the development of air leak from staple lines was evaluated at incremental airway pressures. Unreinforced staples were compared to staples reinforced with bovine pericardium and staples reinforced with expanded polytetrafluorethylene (ePTFE).
RESULTS: Unreinforced staple lines began to leak air at an airway pressure of 20 mm Hg, and > 90% leaked at a pressure of 35 mm Hg. Both bovine pericardium and ePTFE significantly reduced the incidence of air leak at these airway pressures. At higher airway pressures, ePTFE was superior to bovine pericardium.
CONCLUSION: Staple line reinforcement with either material protects against air leak. Patients at risk for elevated airway pressures and/or postoperative ventilator support should be considered for utilization of these staple reinforcing materials.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12475859     DOI: 10.1378/chest.122.6.2146

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  16 in total

1.  Integrated bioabsorbable tissue reinforcement in laparoscopic sleeve gastrectomy.

Authors:  Joshua B Alley; Stephen J Fenton; Michael C Harnisch; Michael N Angeletti; Richard M Peterson
Journal:  Obes Surg       Date:  2011-08       Impact factor: 4.129

Review 2.  Techniques for colorectal anastomosis.

Authors:  Yik Hong Ho; Mohamed Ahmed Tawfik Ashour
Journal:  World J Gastroenterol       Date:  2010-04-07       Impact factor: 5.742

Review 3.  Reinforcement does not necessarily reduce the rate of staple line leaks after sleeve gastrectomy. A review of the literature and clinical experiences.

Authors:  Bo Chen; Andreas Kiriakopoulos; Dimitrios Tsakayannis; Mitchell S Wachtel; Dimitrios Linos; Eldo E Frezza
Journal:  Obes Surg       Date:  2008-09-16       Impact factor: 4.129

Review 4.  Staple line/anastomotic reinforcement and other adjuncts: do they make a difference?

Authors:  Richard Betzold; Jonathan A Laryea
Journal:  Clin Colon Rectal Surg       Date:  2014-12

5.  Perioperative outcome of laparoscopic left lateral liver resection is improved by using staple line reinforcement technique: a case report.

Authors:  Esther C J Consten; Michel Gagner
Journal:  J Gastrointest Surg       Date:  2005-03       Impact factor: 3.452

6.  Clinical report on a computer-controlled hand-actuated stapling system for general lung surgery: the first application in Japan.

Authors:  Yukitoshi Satoh; Yoshio Matsui; Fumihiro Ogawa; Hideki Amano; Hidenori Hara; Kenji Nezu; Akira Iyoda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2009-09-24

7.  A comparison of a single center's experience with three staple line reinforcement techniques in 1,502 laparoscopic sleeve gastrectomy patients.

Authors:  Tyler W Barreto; Paul R Kemmeter; Matthew P Paletta; Alan T Davis
Journal:  Obes Surg       Date:  2015-03       Impact factor: 4.129

8.  A comparison of gastrojejunal anastomoses with or without buttressing in a porcine model.

Authors:  William W Hope; Marc Zerey; Thomas M Schmelzer; William L Newcomb; B Lauren Paton; Jessica J Heath; Richard D Peindl; H James Norton; Amy E Lincourt; B Todd Heniford; Keith S Gersin
Journal:  Surg Endosc       Date:  2008-10-02       Impact factor: 4.584

9.  Early experience with intraluminal reinforcement of stapled gastrojejunostomy during laparoscopic Roux-en-Y gastric bypass.

Authors:  Alan A Saber; Keith R Scharf; Ali Z Turk; Mohamed H Elgamal; Ruvie L M C Martinez
Journal:  Obes Surg       Date:  2008-05       Impact factor: 4.129

10.  A bio-inspired swellable microneedle adhesive for mechanical interlocking with tissue.

Authors:  Seung Yun Yang; Eoin D O'Cearbhaill; Geoffroy C Sisk; Kyeng Min Park; Woo Kyung Cho; Martin Villiger; Brett E Bouma; Bohdan Pomahac; Jeffrey M Karp
Journal:  Nat Commun       Date:  2013       Impact factor: 14.919

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.