Literature DB >> 12459386

Incorporating prior knowledge into beam orientation optimization in IMRT.

Andrei Pugachev1, Lei Xing.   

Abstract

PURPOSE: Selection of beam configuration in currently available intensity-modulated radiotherapy (IMRT) treatment planning systems is still based on trial-and-error search. Computer beam orientation optimization has the potential to improve the situation, but its practical implementation is hindered by the excessive computing time associated with the calculation. The purpose of this work is to provide an effective means to speed up the beam orientation optimization by incorporating a priori geometric and dosimetric knowledge of the system and to demonstrate the utility of the new algorithm for beam placement in IMRT. METHODS AND MATERIALS: Beam orientation optimization was performed in two steps. First, the quality of each possible beam orientation was evaluated using beam's-eye-view dosimetrics (BEVD) developed in our previous study. A simulated annealing algorithm was then employed to search for the optimal set of beam orientations, taking into account the BEVD scores of different incident beam directions. During the calculation, sampling of gantry angles was weighted according to the BEVD score computed before the optimization. A beam direction with a higher BEVD score had a higher probability of being included in the trial configuration, and vice versa. The inclusion of the BEVD weighting in the stochastic beam angle sampling process made it possible to avoid spending valuable computing time unnecessarily at "bad" beam angles. An iterative inverse treatment planning algorithm was used for beam intensity profile optimization during the optimization process. The BEVD-guided beam orientation optimization was applied to an IMRT treatment of paraspinal tumor. The advantage of the new optimization algorithm was demonstrated by comparing the calculation with the conventional scheme without the BEVD weighting in the beam sampling.
RESULTS: The BEVD tool provided useful guidance for the selection of the potentially good directions for the beams to incident and was used to guide the search for the optimal beam configuration. The BEVD-guided sampling improved both optimization speed and convergence of the calculation. A comparison of several five-field IMRT treatment plans obtained with and without BEVD guidance indicated that the computational efficiency was increased by a factor of approximately 10.
CONCLUSION: Incorporation of BEVD information allows for development of a more robust tool for beam orientation optimization in IMRT planning. It enables us to more effectively use the angular degree of freedom in IMRT without paying the excessive computing overhead and brings us one step closer to the goal of automated selection of beam orientations in a clinical environment.

Entities:  

Mesh:

Year:  2002        PMID: 12459386     DOI: 10.1016/s0360-3016(02)03917-2

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  13 in total

1.  Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems.

Authors:  Weihua Mao; Louis Lee; Lei Xing
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

2.  Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

Authors:  Yunzhi Ma; Louis Lee; O Keshet; Paul Keall; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  Simultaneous beam sampling and aperture shape optimization for SPORT.

Authors:  Masoud Zarepisheh; Ruijiang Li; Yinyu Ye; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

4.  Many-isocenter optimization for robotic radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Victoria Y Yu; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2020-02-10       Impact factor: 3.609

5.  An adaptive planning strategy for station parameter optimized radiation therapy (SPORT): Segmentally boosted VMAT.

Authors:  Ruijiang Li; Lei Xing
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

6.  Nonisocentric treatment strategy for breast radiation therapy: a proof of concept study.

Authors:  Ruijiang Li; Lei Xing; Kathleen C Horst; Karl Bush
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-15       Impact factor: 7.038

7.  A data-driven approach to optimal beam/arc angle selection for liver stereotactic body radiation therapy treatment planning.

Authors:  Yang Sheng; Taoran Li; Yaorong Ge; Hui Lin; Wentao Wang; Lulin Yuan; Q Jackie Wu
Journal:  Quant Imaging Med Surg       Date:  2021-12

8.  Validation of in-house knowledge-based planning model for advance-stage lung cancer patients treated using VMAT radiotherapy.

Authors:  Nilesh S Tambe; Isabel M Pires; Craig Moore; Christopher Cawthorne; Andrew W Beavis
Journal:  Br J Radiol       Date:  2020-01-06       Impact factor: 3.039

9.  Automated population-based planning for whole brain radiation therapy.

Authors:  Eduard Schreibmann; Tim Fox; Walter Curran; Hui-Kuo Shu; Ian Crocker
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

10.  Simplifying intensity-modulated radiotherapy plans with fewer beam angles for the treatment of oropharyngeal carcinoma.

Authors:  Robert Takamiya; Brian Missett; Vivian Weinberg; Clayton Akazawa; Pam Akazawa; Andrea Zytkovicz; Mary Kara Bucci; Nancy Lee; Jeanne M Quivey; Ping Xia
Journal:  J Appl Clin Med Phys       Date:  2007-04-11       Impact factor: 2.102

View more