Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography.

Mohammad Golparvar1, Hossein Naddafnia, Mahmood Saghaei.   

Abstract

UNLABELLED: The finger plethysmographic waveform of pulse oximeters is a qualitative indicator of fingertip perfusion. This waveform has been used to assess the depth of anesthesia. Its cyclical changes associated with mechanical ventilation have also been used to detect changes in blood volume under normotensive conditions and has revealed that minimal normotensive hypovolemia can cause a significant increase in the delta-down component of this waveform. Hypovolemia may be associated with hypotension; the latter may be due to causes other than hypovolemia. Because the effects of the hypotension on plethysmographic waveform have not been evaluated, it may be difficult to detect hypovolemia in these conditions by inspecting a plethysmogram. Therefore, we performed this study to evaluate the effect of normovolemic hypotension on characteristics of plethysmographic waveform in 33 adult patients undergoing general anesthesia with controlled hypotension. The delta-down and ventilatory systolic variation components were increased significantly with decreases in systolic blood pressure. The result of this study shows that the effect of pharmacologic hypotension on the plethysmographic waveform of pulse oximeter is similar to that of minimal hypovolemia. Therefore, blood volume may be inaccurately assessed by the inspection of ventilatory-induced cyclical changes of pulse oximetric waveform in the presence of hypotension. IMPLICATIONS: The cyclical respiratory-induced changes in the amplitude of the pulse oximeter waveform can be used to detect normotensive hypovolemia. This study shows that hypotension produces the same effect. Therefore, in hypotensive conditions, we cannot determine the presence of hypovolemia.

Entities:  

Mesh:

Year:  2002        PMID: 12456440     DOI: 10.1097/00000539-200212000-00040

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  11 in total

Review 1.  Accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.

Authors:  Haitao Chu; Yong Wang; Yanfei Sun; Gang Wang
Journal:  J Clin Monit Comput       Date:  2015-08-05       Impact factor: 2.502

2.  Comment on "Pulse oximetry" by Jubran.

Authors:  Aikaterini Maliaga; Stavroula Boulia; Charalampos Martinos; Ilias Andrianakis
Journal:  Intensive Care Med       Date:  2007-02-02       Impact factor: 17.440

3.  Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform.

Authors:  Michael J Gesquiere; Aymen A Awad; David G Silverman; Robert G Stout; Denis H Jablonka; Tyler J Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

4.  The incidence of hypoxemia during surgery: evidence from two institutions.

Authors:  Jesse M Ehrenfeld; Luke M Funk; Johan Van Schalkwyk; Alan F Merry; Warren S Sandberg; Atul Gawande
Journal:  Can J Anaesth       Date:  2010-07-31       Impact factor: 5.063

5.  Pulse perfusion value predicts eye opening after sevoflurane anaesthesia: an explorative study.

Authors:  Bruno Enekvist; Anders Johansson
Journal:  J Clin Monit Comput       Date:  2014-10-02       Impact factor: 2.502

6.  Vasodilation increases pulse pressure variation, mimicking hypovolemic status in rabbits.

Authors:  Glauco A Westphal; Anderson Roman Gonçalves; Antônio Bedin; Raquel Bissacotti Steglich; Eliezer Silva; Luiz Francisco Poli-de-Figueiredo
Journal:  Clinics (Sao Paulo)       Date:  2010-02       Impact factor: 2.365

7.  The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

Authors:  Ling Mou; Quan Gong; Wei Wei; Bo Gao
Journal:  J Clin Monit Comput       Date:  2013-03-10       Impact factor: 2.502

Review 8.  Point-of-care diagnostics to improve maternal and neonatal health in low-resource settings.

Authors:  Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum
Journal:  Lab Chip       Date:  2017-10-11       Impact factor: 6.799

9.  Comparative Evaluation of Hypotensive and Normotensive Anesthesia on LeFort I Osteotomies: A Randomized, Double-Blind, Prospective Clinical Study.

Authors:  Abhivyakti Tewari; Gaurav Singh; Madan Mishra; Amit Gaur; Deepanshu Mallan
Journal:  J Maxillofac Oral Surg       Date:  2020-01-17

10.  Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube.

Authors:  Hosam M Atef; Salah Abd Fattah; Mohammed Emad Abd Gaffer; Ahamed Abd Al Rahman
Journal:  Indian J Anaesth       Date:  2013-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.