Impact of Room Ventilation Rates on Mouse Cage Ventilation and Microenvironment.

Carolyn K. Reeb1, Robert B. Jones, David W. Bearg, Hendrick Bedigian, Beverly Paigen.   

Abstract

To assess the impact of room ventilation on animal cage microenvironment, intracage ventilation rate, temperature, humidity, and concentrations of carbon dioxide and ammonia were monitored in nonpressurized, bonnet-topped mouse cages. Cages on the top, middle, and bottom rows of a mouse rack were monitored at room ventilation rates of 0, 5, 10, and 20 air changes/h (ACH). Ventilation inside the animal cage increased somewhat from 12.8 to 18.9 ACH as room ventilation rate in- creased from 0 to 20 ACH, but the differences were not statistically significant, and most of the increase occurred in cages in the top row nearest to the fresh air supply. Cages containing mice had ventilation rate between 10 and 15 ACH even when room ventilation was reduced to 0 ACH; this ventilation is a result of the thermal heat load of the mice. After 6 days of soiled bedding, intracage ammonia concentration was c 3 ppm at all room ventilation rates and was not affected by increasing room ventilation. Temperature inside cages did not change with increasing ventilation. Humidity inside cages significantly decreased with increasing ventilation, from 55% relative humidity at 5 ACH to 36% relative humidity at 20 ACH. Carbon dioxide concentration decreased from 2,500 ppm to 1,900 ppm when ventilation rate increased from 5 ACH to 10 ACH, but no further significant decrease was observed at 20 ACH. In conclusion, increasing the room ventilation rate higher than 5 ACH did not result in significant improvements in the cage microenvironment.

Entities:  

Year:  1997        PMID: 12456190

Source DB:  PubMed          Journal:  Contemp Top Lab Anim Sci        ISSN: 1060-0558


  10 in total

1.  Mouse housing system using pressurized cages intraventilated by direct-current microfans.

Authors:  Alexandre Martinewski; Caio S C Correia; Nívea L de Souza; José L B Merusse
Journal:  J Am Assoc Lab Anim Sci       Date:  2012-03       Impact factor: 1.232

2.  Bedding-generated particulate matter: implications for rodent studies.

Authors:  Neelakshi Hudda; John L Durant; Alexandra Nemeth; Phyllis Mann; Jocelyn Petitto; Douglas Brugge; Benjamin C Nephew
Journal:  Inhal Toxicol       Date:  2019-11-25       Impact factor: 2.724

3.  Cage change intervals for opossums (Monodelphis domestica) in individually ventilated cages.

Authors:  Sarah O Allison; Jennifer M Criley; Ji Young Kim; Lyndon J Goodly
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-09       Impact factor: 1.232

4.  Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

Authors:  Roger S Geertsema; Claire E Lindsell
Journal:  J Am Assoc Lab Anim Sci       Date:  2015-09       Impact factor: 1.232

Review 5.  Ammonia Measurement in the IVC Microenvironment.

Authors:  Robert B Morrow; Rhonda J Wiler
Journal:  J Am Assoc Lab Anim Sci       Date:  2019-01-31       Impact factor: 1.232

6.  Humidity and cage and bedding temperatures in unoccupied static mouse caging after steam sterilization.

Authors:  Gina M Ward; Kelly Cole; Jennifer Faerber; F Claire Hankenson
Journal:  J Am Assoc Lab Anim Sci       Date:  2009-11       Impact factor: 1.232

7.  Ammonia and carbon dioxide concentrations in disposable and reusable ventilated mouse cages.

Authors:  Jerald Silverman; David W Bays; Sheldon F Cooper; Stephen P Baker
Journal:  J Am Assoc Lab Anim Sci       Date:  2008-03       Impact factor: 1.232

8.  Effect of Ventilated Caging on Water Intake and Loss in 4 Strains of Laboratory Mice.

Authors:  Mackenzie L Nicolaus; Valerie K Bergdall; Ian C Davis; Judy M Hickman-Davis
Journal:  J Am Assoc Lab Anim Sci       Date:  2016       Impact factor: 1.232

Review 9.  Role of mouse allergens in allergic disease.

Authors:  Elizabeth C Matsui
Journal:  Curr Allergy Asthma Rep       Date:  2009-09       Impact factor: 4.806

10.  Effects of Trio and Pair Breeding of Mice on Environmental Parameters and Nasal Pathology and Their Implications for Cage Change Frequency.

Authors:  Kelsey C Carpenter; Sarah E Thurston; Mark J Hoenerhoff; Jennifer L Lofgren
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-02-28       Impact factor: 1.232