Literature DB >> 12450859

A novel fluorescent protein-based biosensor for gram-negative bacteria.

Yan Y Goh1, Bow Ho, Jeak L Ding.   

Abstract

Site-directed mutagenesis of enhanced green fluorescent protein (EGFP) based on rational computational design was performed to create a fluorescence-based biosensor for endotoxin and gram-negative bacteria. EGFP mutants (EGFP(i)) bearing one (G10) or two (G12) strands of endotoxin binding motifs were constructed and expressed in an Escherichia coli host. The EGFP(i) proteins were purified and tested for their efficacy as a novel fluorescent biosensor. After efficient removal of lipopolysaccharide from the E. coli lysates, the binding affinities of the EGFP(i) G10 and G12 to lipid A were established. The K(D) values of 7.16 x 10(-7) M for G10 and 8.15 x 10(-8) M for G12 were achieved. With high affinity being maintained over a wide range of pH and ionic strength, the binding of lipid A/lipopolysaccharide to the EGFP(i) biosensors could be measured as a concentration-dependent fluorescence quenching of the EGFP mutants. The EGFP(i) specifically tagged gram-negative bacteria like E. coli and Pseudomonas aeruginosa, as well as other gram-negative bacteria in contaminated water sampled from the environment. This dual function of the EGFP(i) in detecting both free endotoxin and live gram-negative bacteria forms the basis of the development of a novel fluorescent biosensor.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12450859      PMCID: PMC134398          DOI: 10.1128/AEM.68.12.6343-6352.2002

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  22 in total

Review 1.  Why and how are peptide-lipid interactions utilized for self-defense? Magainins and tachyplesins as archetypes.

Authors:  K Matsuzaki
Journal:  Biochim Biophys Acta       Date:  1999-12-15

Review 2.  Endotoxin removal from protein solutions.

Authors:  D Petsch; F B Anspach
Journal:  J Biotechnol       Date:  2000-01-21       Impact factor: 3.307

3.  Interpretation of biological activity data of bacterial endotoxins by simple molecular models of mechanism of action.

Authors:  V Frecer; B Ho; J L Ding
Journal:  Eur J Biochem       Date:  2000-02

4.  Application of a novel apparatus, the quartz chemical analyzer, to the determination of endotoxin in blood.

Authors:  R Homma; Y Takada; I Karube; K Kimura; H Muramatsu
Journal:  Anal Biochem       Date:  1992-08-01       Impact factor: 3.365

5.  Assay of pyrogens by interleukin-6 release from monocytic cell lines.

Authors:  Y S Taktak; S Selkirk; A F Bristow; A Carpenter; C Ball; B Rafferty; S Poole
Journal:  J Pharm Pharmacol       Date:  1991-08       Impact factor: 3.765

6.  Development of a biosensor for E. coli based on a flexural plate wave (FPW) transducer.

Authors:  J C Pyun; H Beutel; J U Meyer; H H Ruf
Journal:  Biosens Bioelectron       Date:  1998-10-01       Impact factor: 10.618

7.  Green fluorescent protein purification by organic extraction.

Authors:  A V Yakhnin; L M Vinokurov; A K Surin; Y B Alakhov
Journal:  Protein Expr Purif       Date:  1998-12       Impact factor: 1.650

8.  Use of the green fluorescent protein and its mutants in quantitative fluorescence microscopy.

Authors:  G H Patterson; S M Knobel; W D Sharif; S R Kain; D W Piston
Journal:  Biophys J       Date:  1997-11       Impact factor: 4.033

9.  Human monocytoid cell lines as indicators of endotoxin: comparison with rabbit pyrogen and Limulus amoebocyte lysate assay.

Authors:  S Eperon; D De Groote; G Werner-Felmayer; T W Jungi
Journal:  J Immunol Methods       Date:  1997-09-24       Impact factor: 2.303

10.  Immunomagnetic separation and flow cytometry for rapid detection of Escherichia coli O157:H7.

Authors:  K H Seo; R E Brackett; J F Frank; S Hilliard
Journal:  J Food Prot       Date:  1998-07       Impact factor: 2.077

View more
  4 in total

1.  Spatial expression of a mercury-inducible green fluorescent protein within a nanoporous latex-based biosensor coating.

Authors:  Janet L Schottel; Paul M Orwin; C Ron Anderson; Michael C Flickinger
Journal:  J Ind Microbiol Biotechnol       Date:  2008-01-08       Impact factor: 3.346

2.  Complementation and reconstitution of fluorescence from circularly permuted and truncated green fluorescent protein.

Authors:  Yao-ming Huang; Christopher Bystroff
Journal:  Biochemistry       Date:  2009-02-10       Impact factor: 3.162

Review 3.  Molecular Recognition and Specific Interactions for Biosensing Applications.

Authors:  Dong Chung Kim; Dae Joon Kang
Journal:  Sensors (Basel)       Date:  2008-10-23       Impact factor: 3.576

4.  Development of a Sensitive Escherichia coli Bioreporter Without Antibiotic Markers for Detecting Bioavailable Copper in Water Environments.

Authors:  Yilin Pang; Xiaojun Ren; Jianghui Li; Feng Liang; Xiaoyu Rao; Yang Gao; Wenhe Wu; Dong Li; Juanjuan Wang; Jianguo Zhao; Xufen Hong; Fengying Jiang; Wu Wang; Huaibin Zhou; Jianxin Lyu; Guoqiang Tan
Journal:  Front Microbiol       Date:  2020-01-24       Impact factor: 5.640

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.