Literature DB >> 9678161

Immunomagnetic separation and flow cytometry for rapid detection of Escherichia coli O157:H7.

K H Seo1, R E Brackett, J F Frank, S Hilliard.   

Abstract

A rapid method for detecting Escherichia coli O157:H7 combining immunomagnetic beads (IMB) and flow cytometry was developed. Labeling antigens separated by IMB with fluorescent antibody enabled the detection of < 10(3) CFU bacteria per ml in pure culture. The optimum concentration of magnetic beads for flow cytometry was lower (ca. 10(5) particles per ml) than that reported for conventional IMB assay (more than 6 x 10(6) to 8 x 10(6) particles per ml). Immunomagnetic separation and flow cytometry (IMFC) were evaluated for detecting E. coli O157:H7 in the presence of a competing microorganism and for detecting antibodies in potassium phosphate buffer. The total assay time from separating antigens with IMB to analyzing with flow cytometry was about 1 h. IMFC detected 10(3) to 10(4) CFU of E. coli O157:H7 per ml in ground beef enrichment broth and could effectively discriminate between E. coli O157:H7 and competing natural flora. The new assay system provides another approach to separation and detection of low populations of pathogens and shows potential for detecting low concentrations of toxins and other soluble antigens directly from food in a short time.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9678161     DOI: 10.4315/0362-028x-61.7.812

Source DB:  PubMed          Journal:  J Food Prot        ISSN: 0362-028X            Impact factor:   2.077


  4 in total

Review 1.  Emerging nanotechnology-based strategies for the identification of microbial pathogenesis.

Authors:  Charalambos Kaittanis; Santimukul Santra; J Manuel Perez
Journal:  Adv Drug Deliv Rev       Date:  2009-11-13       Impact factor: 15.470

2.  Solid-phase capture of proteins, spores, and bacteria.

Authors:  B C Weimer; M K Walsh; C Beer; R Koka; X Wang
Journal:  Appl Environ Microbiol       Date:  2001-03       Impact factor: 4.792

3.  A novel fluorescent protein-based biosensor for gram-negative bacteria.

Authors:  Yan Y Goh; Bow Ho; Jeak L Ding
Journal:  Appl Environ Microbiol       Date:  2002-12       Impact factor: 4.792

4.  Protein A-Mediated Binding of Staphylococcus spp. to Antibodies in Flow Cytometric Assays and Reduction of This Binding by Using Fc Receptor Blocking Reagent.

Authors:  Ultan P Cronin; Laura Girardeaux; Elaine O'Meara; Martin G Wilkinson
Journal:  Appl Environ Microbiol       Date:  2020-08-18       Impact factor: 4.792

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.