Literature DB >> 12450720

Glass ionomer microleakage from preparations by an Er/YAG laser or a high-speed handpiece.

Brian C Quo1, James L Drummond, Anne Koerber, Shahrbanoo Fadavi, Indru Punwani.   

Abstract

OBJECTIVE: The purpose of this study was to compare microleakage of glass ionomer materials (GIC) using two different modes of cavity preparation: a high-speed hand piece and an erbium/yttrium-aluminum-garnet (Er/YAG) laser.
METHODS: Eighty caries free permanent molar teeth had class V preparations cut on both the buccal and lingual surfaces. The high-speed hand piece was used to prepare a class V cavity preparation on the buccal surface and an Er/YAG laser was used to prepare a class V cavity preparation on the lingual surface. GIC or resin modified GIC was used as the restorative material. The teeth were thermocycled for 7000 cycles, placed in 2% basic fushin for 24h, sectioned in the center of each restoration, and analyzed under a stereomicroscope.
RESULTS: There was no statistical difference in microleakage between the two modes of cavity preparations. The gingival margins had more microleakage than the occlusal margins for both GIC materials and the resin modified GIC showed significantly more leakage than the conventional GIC.
CONCLUSIONS: The Er/YAG laser provided an equivalent method of tooth removal when evaluated for microleakage of GIC materials compared to a high-speed hand piece.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12450720     DOI: 10.1016/s0300-5712(02)00011-8

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  14 in total

1.  Influence of different conditioning methods on the shear bond strength of novel light-curing nano-ionomer restorative to enamel and dentin.

Authors:  Yonca Korkmaz; Emre Ozel; Nuray Attar; Ceren Ozge Bicer
Journal:  Lasers Med Sci       Date:  2009-08-18       Impact factor: 3.161

2.  Tensile bond strength of sealants following Er:YAG laser etching compared to acid etching in permanent teeth.

Authors:  Sima Shahabi; Hossein G Bagheri; Kosar Ramazani
Journal:  Lasers Med Sci       Date:  2011-02-19       Impact factor: 3.161

3.  Comparison of Micro-Leakage from Resin-Modified Glass Ionomer Restorations in Cavities Prepared by Er:YAG (Erbium-Doped Yttrium Aluminum Garnet) Laser and Conventional Method in Primary Teeth.

Authors:  Zahra Bahrololoomi; Forooghosadat Razavi; Ali Asghar Soleymani
Journal:  J Lasers Med Sci       Date:  2014

4.  Microleakage of Er:YAG laser and dental bur prepared cavities in primary teeth restored with different adhesive restorative materials.

Authors:  Ali Baghalian; Yahya B Nakhjavani; Tabassom Hooshmand; Pouria Motahhary; Hoda Bahramian
Journal:  Lasers Med Sci       Date:  2012-11-08       Impact factor: 3.161

5.  Microleakage in Class V cavities with self-etching adhesive system and conventional rotatory or laser Er,Cr:YSGG.

Authors:  K Trelles; J Arnabat; T España-Tost
Journal:  Laser Ther       Date:  2012-12-26

Review 6.  Laser restorative dentistry in children and adolescents.

Authors:  G Olivi; M D Genovese
Journal:  Eur Arch Paediatr Dent       Date:  2011-04

7.  Influence of cavity preparation with Er,Cr:YSGG laser and restorative materials on in situ secondary caries development.

Authors:  Ana Carolina Tedesco Jorge; Alessandra Cassoni; Patrícia Moreira de Freitas; André Figueiredo Reis; Aldo Brugnera Junior; Jose Augusto Rodrigues
Journal:  Photomed Laser Surg       Date:  2015-02-05       Impact factor: 2.796

8.  Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium-aluminum-garnet laser and bur.

Authors:  Yonca Korkmaz; Emre Ozel; Nuray Attar; Ceren Ozge Bicer; Erhan Firatli
Journal:  Lasers Med Sci       Date:  2009-04-27       Impact factor: 3.161

9.  Microleakage of glass ionomer formulations after erbium:yttrium-aluminium-garnet laser preparation.

Authors:  Katleen I M Delmé; Peter J Deman; Mieke A A De Bruyne; Samir Nammour; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2008-08-21       Impact factor: 3.161

10.  Comparison of the Shear Bond Strength of Resin Modified Glass Ionomer to Enamel in Bur-Prepared or Lased Teeth (Er:YAG).

Authors:  Ahmad Jafari; Sima Shahabi; Nasim Chiniforush; Ali Shariat
Journal:  J Dent (Tehran)       Date:  2013-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.