Assessment of backside wear from the analysis of 55 retrieved tibial inserts.

S Li1, G Scuderi, B D Furman, S Bhattacharyya, J J Schmieg, J N Insall.   

Abstract

Fifty-five retrieved tibial inserts with four different locking mechanisms were evaluated for evidence for polyethylene wear between the inferior surface of the tibial insert and metal tray. This type of wear will be referred to as backside wear. Backside wear was assessed by evaluating manufacturer's stamped markings on the inferior polyethylene surface. Because these markings are embossed into the polyethylene surface, they were used as indicators of backside wear. Decreases in the depths of markings indicated that backside wear was clearly evident, regardless of design, in 24 (44%) of the inserts. In eight of these 24 inserts, the manufacturer's stamped markings were removed completely. The amount of polyethylene wear was as a high as 591 mg from the inferior surface. This corresponds to a polyethylene wear rate from the backside of the tibial insert of greater than 100 mg per year, which is two to four times higher than wear rates associated with total hip replacements. The current work provides direct evidence of backside wear in all four tibial insert designs. Backside wear of tibial inserts can be a significant contributor to polyethylene wear in total knee arthroplasty. Close attention should be given to the fixation of tibial inserts to metal trays by manufacturers and surgeons.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12439241     DOI: 10.1097/00003086-200211000-00013

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  13 in total

1.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  In vitro quantification of wear in tibial inserts using microcomputed tomography.

Authors:  Matthew G Teeter; Douglas D R Naudie; David D McErlain; Jan-M Brandt; Xunhua Yuan; Steven J Macdonald; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

3.  Changes in surface topography at the TKA backside articulation following in vivo service: a retrieval analysis.

Authors:  Richard J Holleyman; Susan C Scholes; David Weir; Simon S Jameson; Jim Holland; Tom J Joyce; David J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-07       Impact factor: 4.342

4.  Polished trays reduce backside wear independent of post location in posterior-stabilized TKAs.

Authors:  Matthew P Abdel; Mark W Gesell; Christen W Hoedt; Kathleen N Meyers; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-04-15       Impact factor: 4.176

5.  Does increased topside conformity in modular total knee arthroplasty lead to increased backside wear?

Authors:  Ran Schwarzkopf; Richard D Scott; Evan M Carlson; John H Currier
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

6.  CORR Insights®: Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2018-03       Impact factor: 4.176

7.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

8.  Polyethylene wear is influenced by manufacturing technique in modular TKA.

Authors:  Adolph V Lombardi; Bradley S Ellison; Keith R Berend
Journal:  Clin Orthop Relat Res       Date:  2008-09-13       Impact factor: 4.176

9.  Surgeon-defined assessment is a poor predictor of knee balance in total knee arthroplasty: a prospective, multicenter study.

Authors:  Samuel J MacDessi; Jil A Wood; Ashish D Diwan; Ian A Harris
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-03-13       Impact factor: 4.342

10.  Backside wear in modern total knee designs.

Authors:  Prakash Jayabalan; Bridgette D Furman; Jocelyn M Cottrell; Timothy M Wright
Journal:  HSS J       Date:  2007-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.