Literature DB >> 12438052

Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease.

Kai Uwe Juergens1, Matthias Grude, Eva Maria Fallenberg, Christian Opitz, Thomas Wichter, Walter Heindel, Roman Fischbach.   

Abstract

OBJECTIVE: Retrospectively ECG-gated three-dimensional volume data from multidetector CT (MDCT) coronary angiography enable image reconstruction of the cardiac cycle in the diastolic and systolic phases. The objective of our study was to investigate the feasibility of determining left ventricular function from MDCT coronary angiography data sets in 22 patients with coronary artery disease and to study the correlation of MDCT results with those of functional data from biplane cineventriculography.
CONCLUSION: Multiplanar reformations from three-dimensional MDCT data allowed good delineation of endocardial and epicardial left ventricular contours. In patients evaluated for coronary artery disease, MDCT coronary angiography with retrospective ECG gating provides functional data in an acceptable correlation (r = 0.8; p < 0.05) to biplane cineventriculography.

Entities:  

Mesh:

Year:  2002        PMID: 12438052     DOI: 10.2214/ajr.179.6.1791545

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  29 in total

1.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

2.  Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography.

Authors:  Martin Heuschmid; Julia K Rothfuss; Stephen Schroeder; Michael Fenchel; Norbert Stauder; Christof Burgstahler; Andreas Franow; Ronald S Kuzo; Axel Kuettner; Stephan Miller; Claus D Claussen; Andreas F Kopp
Journal:  Eur Radiol       Date:  2005-10-08       Impact factor: 5.315

Review 3.  Non-invasive multislice CT coronary imaging.

Authors:  Nico R Mollet; Filippo Cademartiri; Pim J de Feyter
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

4.  Left ventricular function studied with MDCT.

Authors:  Kai Uwe Juergens; Roman Fischbach
Journal:  Eur Radiol       Date:  2005-08-20       Impact factor: 5.315

5.  Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm.

Authors:  Georg Mühlenbruch; Marco Das; Christian Hohl; Joachim E Wildberger; Daniel Rinck; Thomas G Flohr; Ralf Koos; Christian Knackstedt; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2005-12-22       Impact factor: 5.315

6.  Mutidetector-row CT and quantitative gated SPECT for the assessment of left ventricular function in small hearts: the cardiac physical phantom study using a combined SPECT/CT system.

Authors:  Daisuke Utsunomiya; Seiji Tomiguchi; Kazuo Awai; Shinya Shiraishi; Takeshi Nakaura; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2006-02-03       Impact factor: 5.315

7.  Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging.

Authors:  Roman Fischbach; Kai Uwe Juergens; Murat Ozgun; David Maintz; Matthias Grude; Harald Seifarth; Walter Heindel; Thomas Wichter
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

Review 8.  Cardiac CT: coronary arteries and beyond.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-10-26       Impact factor: 5.315

Review 9.  Comprehensive cardiac CT study: evaluation of coronary arteries, left ventricular function, and myocardial perfusion--is it possible?

Authors:  Ricardo C Cury; Koen Nieman; Michael D Shapiro; Khurram Nasir; Roberto C Cury; Thomas J Brady
Journal:  J Nucl Cardiol       Date:  2007-04       Impact factor: 5.952

10.  Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: comparison with cine magnetic resonance imaging.

Authors:  Bénédicte Belge; Emmanuel Coche; Agnès Pasquet; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Eur Radiol       Date:  2006-03-02       Impact factor: 5.315

View more