Literature DB >> 12438025

Accuracy of interpretation of CT scans: comparing PACS monitor displays and hard-copy images.

Bruce I Reiner1, Eliot L Siegel, Frank J Hooper.   

Abstract

OBJECTIVE: The purpose of this study was to determine the relative diagnostic accuracy of radiologists in the interpretation of CT scans using a computer workstation in comparison with using film.
MATERIALS AND METHODS: Four board-certified radiologists with extensive soft-copy experience interpreted 117 CT scans in four anatomic regions using films displayed on an alternator and images displayed on a four-monitor workstation. The radiologists were asked to interpret the scans in their usual fashion and were aware that both the time required to review the study and the accuracy of the reports were being assessed. The radiologists' diagnostic impressions were compared with those of a consensus panel and scored for accuracy.
RESULTS: Soft-copy interpretation using computer workstations was found to produce statistically significant improvement in combined measurements of sensitivity, specificity, and overall accuracy for chest, brain, and chest-abdominal CT scans compared with film interpretation.
CONCLUSION: PACS (picture archiving and communication system) offers radiologists the potential for improved accuracy in CT interpretation compared with traditional film-based interpretation.

Entities:  

Mesh:

Year:  2002        PMID: 12438025     DOI: 10.2214/ajr.179.6.1791407

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

Review 1.  Evolution of the digital revolution: a radiologist perspective.

Authors:  Bruce I Reiner; Eliot L Siegel; Khan Siddiqui
Journal:  J Digit Imaging       Date:  2004-01-30       Impact factor: 4.056

2.  Comparison of PACS and hard-copy 51-inch radiographs for measuring leg length and deformity.

Authors:  Saurabh Khakharia; Daniel Bigman; Austin T Fragomen; Helene Pavlov; S Robert Rozbruch
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

Review 3.  Multi-detector computed tomography of acute abdomen.

Authors:  Sebastian Leschka; Hatem Alkadhi; Simon Wildermuth; Borut Marincek
Journal:  Eur Radiol       Date:  2005-08-27       Impact factor: 5.315

4.  Picture, archiving and communication system in the Italian NHS: a primer on diffusion and evaluation analysis.

Authors:  Luca Buccoliero; Stefano Calciolari; Marta Marsilio; Elisa Mattavelli
Journal:  J Digit Imaging       Date:  2008-02-22       Impact factor: 4.056

5.  Virtual organization of hospital medical imaging: a user satisfaction survey.

Authors:  Claude Sicotte; Guy Paré; Kobena Kra Bini; Marie-Pierre Moreault; Guy Laverdure
Journal:  J Digit Imaging       Date:  2009-07-09       Impact factor: 4.056

6.  Laparoscopic intraoperative navigation surgery for gastric cancer using real-time rendered 3D CT images.

Authors:  Shuji Takiguchi; Y Fujiwara; M Yamasaki; H Miyata; K Nakajima; T Nishida; M Sekimoto; M Hori; H Nakamura; M Mori; Y Doki
Journal:  Surg Today       Date:  2014-08-12       Impact factor: 2.549

7.  Digital Paper Prints as Replacement for LASER Films: A Study of Intra-Observer Agreement for Wrist Radiographic Findings in Rickets.

Authors:  Abhinav Jain; Priyanka Gupta; Surinder Pal Singh Anand; Archana Dang
Journal:  J Clin Diagn Res       Date:  2016-08-01

8.  Can paper replace laser film to communicate the results of wrist radiographs in trauma cases? A reproducibility study of the reading of wrist trauma case radiographs on a PACS workstation, laser film, and paper.

Authors:  Pedro Teixeira; Jean-Philippe Zabel; Cédric Baumann; Stéphane Albizzati; Henry Coudane; Daniel Winninger; Alain Blum
Journal:  J Digit Imaging       Date:  2013-12       Impact factor: 4.056

9.  Digital imaging data on CD-R: a time trap for orthopaedic surgeons in outpatient clinics.

Authors:  Stephanie Juenemann; Carol Hasler; Reinald Brunner
Journal:  J Child Orthop       Date:  2008-12-12       Impact factor: 1.548

10.  Is targeted reconstruction necessary for evaluating contrast-enhanced chest computed tomography using a liquid crystal display monitor?

Authors:  Yoshiyuki Ozawa; Masaki Hara; Hidekazu Oshima; Masanori Kitase; Kazuya Ohashi; Yuta Shibamoto
Journal:  Radiat Med       Date:  2008-10-31
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.