PURPOSE: To determine the value of multiplanar and volume-rendered modes of analysis versus axial imaging for the optimal placement of probes in spiral image computed tomography (CT)-guided radiofrequency (RF) ablation of liver lesions.
MATERIALS AND METHODS: Thirty-two malignant hepatic lesions in 21 patients with hepatocellular carcinoma (n = 10) or metastases (n = 11) were treated with percutaneous RF ablation. After axial CT-guided placement (biopsy mode) of the probe in the tumor, a contrast-enhanced spiral image set was obtained and data were viewed in contiguous axial sections and the multiplanar and volume-rendered modes. The position of the probe was characterized as "central," "marginal," or "outside," corresponding with its position in the lesion. Outside positioning was corrected before ablation was performed and, in cases of "marginal" positioning, the probe was redirected after initial ablative therapy in the same session.
RESULTS: Multiplanar and volume-rendered analysis reclassified the needle position before 14 of 32 RF ablation procedures (44%; P =.0034, McNemar test). In 10 cases, probe positions considered "central" on biopsy-mode images were found to be "marginal" with multiplanar/volume-rendered analysis. In three cases, probe positions considered "marginal" on biopsy-mode images were found to be "outside" with multiplanar/volume-rendered analysis. In one lesion, multiplanar/volume-rendered analysis upgraded the probe position from "marginal" to "central." Comparison of multiplanar and volume-rendered analysis revealed no difference in probe positioning. The time requirements to obtain additional data were 159 seconds +/- 49 for multiplanar analysis and 434 seconds +/- 78 for volume-rendered analysis.
CONCLUSION: A contrast-enhanced spiral CT image data set with multiplanar reformations to verify an optimal probe location after axial CT-guided needle placement should be obtained before RF ablation of liver lesions.

Entities:  

Mesh:

Year:  2002        PMID: 12427816     DOI: 10.1016/s1051-0443(07)61958-7

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  14 in total

Review 1.  Local recurrence after hepatic radiofrequency coagulation: multivariate meta-analysis and review of contributing factors.

Authors:  Stefaan Mulier; Yicheng Ni; Jacques Jamart; Theo Ruers; Guy Marchal; Luc Michel
Journal:  Ann Surg       Date:  2005-08       Impact factor: 12.969

2.  Accuracy of combined PET/CT in image-guided interventions of liver lesions: an ex-vivo study.

Authors:  Patrick Veit; Christiane Kuehle; Thomas Beyer; Hilmar Kuehl; Andreas Bockisch; Gerald Antoch
Journal:  World J Gastroenterol       Date:  2006-04-21       Impact factor: 5.742

3.  Segmentation of elastographic images using a coarse-to-fine active contour model.

Authors:  Wu Liu; James A Zagzebski; Tomy Varghese; Charles R Dyer; Udomchai Techavipoo; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2006-03       Impact factor: 2.998

4.  Incorporation of preprocedural PET into CT-guided radiofrequency ablation of hepatic metastases: a nonrigid image registration validation study.

Authors:  Peng Lei; Omkar Dandekar; David Widlus; Raj Shekhar
Journal:  J Digit Imaging       Date:  2009-05-27       Impact factor: 4.056

5.  In vivo guidance and assessment of liver radio-frequency ablation with acoustic radiation force elastography.

Authors:  Brian J Fahey; Rendon C Nelson; Stephen J Hsu; David P Bradway; Douglas M Dumont; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2008-05-09       Impact factor: 2.998

6.  Tumor boundary estimation through time-domain peaks monitoring: numerical predictions and experimental results in tissue-mimicking phantoms.

Authors:  Peng Wang; Christopher L Brace; Mark C Converse; John G Webster
Journal:  IEEE Trans Biomed Eng       Date:  2009-06-26       Impact factor: 4.538

7.  Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

Authors:  Junichi Tokuda; William Plishker; Meysam Torabi; Olutayo I Olubiyi; George Zaki; Servet Tatli; Stuart G Silverman; Raj Shekher; Nobuhiko Hata
Journal:  Acad Radiol       Date:  2015-03-14       Impact factor: 3.173

8.  Multimodality non-rigid image registration for planning, targeting and monitoring during CT-guided percutaneous liver tumor cryoablation.

Authors:  Haytham Elhawary; Sota Oguro; Kemal Tuncali; Paul R Morrison; Servet Tatli; Paul B Shyn; Stuart G Silverman; Nobuhiko Hata
Journal:  Acad Radiol       Date:  2010-11       Impact factor: 3.173

9.  Tissue dielectric measurement using an interstitial dipole antenna.

Authors:  Peng Wang; Christopher L Brace
Journal:  IEEE Trans Biomed Eng       Date:  2011-09-12       Impact factor: 4.538

10.  Detection of residual tumor after radiofrequency ablation of liver metastasis with dual-modality PET/CT: initial results.

Authors:  Patrick Veit; Gerald Antoch; Hrvoje Stergar; Andreas Bockisch; Michael Forsting; Hilmar Kuehl
Journal:  Eur Radiol       Date:  2005-05-03       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.