Literature DB >> 12423602

Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro.

M A Germain1, A Hatton, S Williams, J B Matthews, M H Stone, J Fisher, E Ingham.   

Abstract

Concern over polyethylene wear particle induced aseptic loosening of metal-on-polyethylene hip prostheses has led to renewed interest in alternative materials such as metal-on-metal and alumina ceramic-on-alumina ceramic for total hip replacement. This study compared the effects of clinically relevant cobalt-chromium and alumina ceramic wear particles on the viability of U937 histiocytes and L929 fibroblasts in vitro. Clinically relevant cobalt-chromium wear particles were generated using a flat pin-on-plate tribometer. The mean size of the clinically relevant metal particles was 29.5+/-6.3 nm (range 5-200 nm). Clinically relevant alumina ceramic particles were generated in the Leeds MkII anatomical hip simulator from a Mittelmieier prosthesis using micro-separation motion. This produced particles with a bimodal size distribution. The majority (98%) of the clinically relevant alumina ceramic wear debris was 5-20 nm in size. The cytotoxicity of the clinically relevant wear particles was compared to commercially available cobalt-chromium (9.87 microm+/-5.67) and alumina ceramic (0.503+/-0.19 microm) particles. The effects of the particles on the cells over a 5 day period at different particle volume (microm(3)) to cell number ratios were tested and viability determined using ATP-Lite(TM). Clinically relevant cobalt-chromium particles 50 and 5 microm(3) per cell reduced the viability of U937 cells by 97% and 42% and reduced the viability of L929 cells by 95% and 73%, respectively. At 50 microm(3) per cell, the clinically relevant ceramic particles reduced U937 cell viability by 18%. None of the other concentrations of the clinically relevant particles were toxic. The commercial cobalt-chromium and alumina particles did not affect the viability of either the U937 histiocytes or the L929 fibroblasts.Thus at equivalent particle volumes the clinically relevant cobalt-chromium particles were more toxic then the alumina ceramic particles. This study has emphasised the fact that the nature, size and volume of particles are important in assessing biological effects of wear debris on cells in vitro.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12423602     DOI: 10.1016/s0142-9612(02)00360-5

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  35 in total

1.  Comparison of the cytotoxic and inflammatory responses of titanium particles with different methods for endotoxin removal in RAW264.7 macrophages.

Authors:  Huifeng Ding; Zhenan Zhu; Tingting Tang; Degang Yu; Bo Yu; Kerong Dai
Journal:  J Mater Sci Mater Med       Date:  2012-02-23       Impact factor: 3.896

2.  [Reasons for failure of hip resurfacing implants. A failure analysis based on 250 revision specimens].

Authors:  M M Morlock; N Bishop; F Stahmer; J Zustin; G Sauter; M Hahn; M Krause; W Rüther; M Amling
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

Review 3.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

Review 4.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

5.  Titanium dioxide (TiO(2)) nanoparticles filled poly(D,L lactid acid) (PDLLA) matrix composites for bone tissue engineering.

Authors:  L-C Gerhardt; G M R Jell; A R Boccaccini
Journal:  J Mater Sci Mater Med       Date:  2007-01-09       Impact factor: 3.896

Review 6.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

Review 7.  The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction.

Authors:  Emmanuel Gibon; Luis A Córdova; Laura Lu; Tzu-Hua Lin; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-04-15       Impact factor: 3.368

8.  High survivorship with a titanium-encased alumina ceramic bearing for total hip arthroplasty.

Authors:  James A D'Antonio; William N Capello; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

9.  Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris.

Authors:  G I Howling; E Ingham; H Sakoda; T D Stewart; J Fisher; A Antonarulrajah; S Appleyard; B Rand
Journal:  J Mater Sci Mater Med       Date:  2004-01       Impact factor: 3.896

10.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.