Literature DB >> 12422115

Influence of stent design and material composition on procedure outcome.

Julio C Palmaz1, Steven Bailey, Denes Marton, Eugene Sprague.   

Abstract

Although intravascular stents have received widespread application, significant limitations remain. In stent restenosis, the most pervasive problem affecting stents, is related in part to technical aspects of the device. Design features of the stent that influence outcome have been identified and optimized for improved performance. The influence of stent materials on critical aspects of healing, such as thrombotic, inflammatory, and hyperplastic responses, are less well understood. For this reason, significant progress in this area is lacking. Current stents have significant contamination with industrial impurities on the surface and in the bulk. This fact adds to the difficulties in interpreting the biologic reaction of the host to the device. Better understanding of the basic biologic interactions is the path to significant improvement.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12422115     DOI: 10.1067/mva.2002.129113

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  9 in total

Review 1.  The future of drug eluting stents.

Authors:  R R Anis; K R Karsch
Journal:  Heart       Date:  2005-10-10       Impact factor: 5.994

2.  The surface modification of stainless steel and the correlation between the surface properties and protein adsorption.

Authors:  Chan-Koo Kang; Yoon-Sik Lee
Journal:  J Mater Sci Mater Med       Date:  2007-02-03       Impact factor: 3.896

Review 3.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

4.  Stent strut streamlining and thickness reduction promote endothelialization.

Authors:  Duy T Nguyen; Alexander F Smith; Juan M Jiménez
Journal:  J R Soc Interface       Date:  2021-08-18       Impact factor: 4.293

5.  Prospective evaluation of an ultrathin strut biodegradable polymer-coated sirolimus-eluting stent: 12 months' results from the S-FLEX UK registry.

Authors:  Anirban Choudhury; Scot Garg; Jamie Smith; Andrew Sharp; Sergio Nabais de Araujo; Anoop Chauhan; Nikhil Patel; Benjamin Wrigley; Sudipta Chattopadhyay; Azfar G Zaman
Journal:  BMJ Open       Date:  2019-10-11       Impact factor: 2.692

6.  Self-expandable nitinol stent placement in homocysteinemic porcine aorta.

Authors:  Luís Henrique Gil França; Adamastor Humberto Pereira; Sílvio César Perini
Journal:  Clinics (Sao Paulo)       Date:  2008-04       Impact factor: 2.365

7.  Bring that pioneering spirit back! A 25-year perspective on the vascular stent.

Authors:  Julio C Palmaz
Journal:  Cardiovasc Intervent Radiol       Date:  2007-09-06       Impact factor: 2.740

8.  Biological effect of microengineered grooved stents on strut healing: a randomised OCT-based comparative study in humans.

Authors:  Boris Vesga; Hector Hernandez; Sergio Higuera; Pawel Gasior; Dario Echeveri; Juan A Delgado; Antonio Dager; Camilo Arana; Charles Simonton; Akiko Maehara; Julio Palmaz; Juan F Granada
Journal:  Open Heart       Date:  2017-05-22

Review 9.  Understanding the Impact of Stent and Scaffold Material and Strut Design on Coronary Artery Thrombosis from the Basic and Clinical Points of View.

Authors:  Atsushi Sakamoto; Hiroyuki Jinnouchi; Sho Torii; Renu Virmani; Aloke V Finn
Journal:  Bioengineering (Basel)       Date:  2018-09-04
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.