Shedding new light on composite polymerization.

W Frank Caughman1, F A Rueggeberg.   

Abstract

Life usually gets simpler, but in the case of photocuring dental restorative materials, just the opposite is true. Confusing and contradictory barrages of clinical claims have been made with the ever-growing variety of light-curing sources available today. Often, laboratory research or clinical studies related to these systems are lacking prior to their being introduced to the market, leaving the clinician to become the "testing ground." Manufacturers prefer to market the newest technology available, yet, depending on the type of practice and composite system in use, such "state-of-the-art" devices may offer no advantage. For some clinicians, changing to a "fast cure" composite in combination with a traditional QTH light, instead of purchasing a $4,000 PAC light, may be the only improvement in efficiency needed. However, others may want to spend as little time as possible per procedure and do not mind investing in the newest, yet "unproven" technology. Either way, today's clinician needs to be wary of the many claims made by manufacturers of all light-curing units. It is prudent that the clinician, prior to selecting a device, aggressively ask questions and dig for the truth before "buying into" a particular unit or system philosophy. At stake are the durability of restorations, the satisfaction of patient and the well-earned reputation of the operator.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12413231

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  6 in total

1.  Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure.

Authors:  Anders Lindberg; Anne Peutzfeldt; Jan W V van Dijken
Journal:  Clin Oral Investig       Date:  2005-04-07       Impact factor: 3.573

2.  Effect of three types of light-curing units on 5-year colour changes of light-cured composite.

Authors:  Onjen Tak; Subutay Han Altintas; Nilgun Ozturk; Aslihan Usumez
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

3.  Halogen and LED light curing of composite: temperature increase and Knoop hardness.

Authors:  L F Schneider; S Consani; L Correr-Sobrinho; A B Correr; M A Sinhoreti
Journal:  Clin Oral Investig       Date:  2006-01-10       Impact factor: 3.573

4.  Evaluation of residual monomer release after polymerization of different restorative materials used in pediatric dentistry.

Authors:  Gülsüm Duruk; Sibel Akküç; Yılmaz Uğur
Journal:  BMC Oral Health       Date:  2022-06-13       Impact factor: 3.747

5.  Influence of different thermopolymerization methods on composite resin microhardness.

Authors:  Marlon-Ferreira Dias; Luís-Felipe Espíndola-Castro; Paulo-Cardoso Lins-Filho; Hilcia-Mezzalira Teixeira; Claudio-Heliomar-Vicente Silva; Renata-Pedrosa Guimarães
Journal:  J Clin Exp Dent       Date:  2020-04-01

6.  Effect of light-curing units and activation mode on polymerization shrinkage and shrinkage stress of composite resins.

Authors:  Lawrence Gonzaga Lopes; Eduardo Batista Franco; José Carlos Pereira; Rafael Francisco Lia Mondelli
Journal:  J Appl Oral Sci       Date:  2008 Jan-Feb       Impact factor: 2.698