Literature DB >> 12408480

Effect of 176Lu background on singles transmission for LSO-based PET cameras.

J S Huber1, W W Moses, W F Jones, C C Watson.   

Abstract

We explore how the radioactive background from naturally occurring 176Lu affects single photon transmission imaging for lutetium orthosilicate (LSO) scintillator-based PET cameras by estimating the transmission noise equivalent count rate (NECR) including this background. Assuming a typical PET camera geometry (80 cm detector ring diameter), we use a combination of measurement and analytic computation to estimate the counting rates due to transmission, scatter and background events as a function of singles transmission source strength. We then compute a NECR for singles transmission. We find that the presence of radiation from the naturally occurring 176Lu reduces the NECR by 60% or higher for source strengths less than 10 mCi, and that a 25% reduction of the NECR can occur even with a source strength of 40 mCi.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12408480     DOI: 10.1088/0031-9155/47/19/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Feasibility of template-guided attenuation correction in cat brain PET imaging.

Authors:  Jin Su Kim; Jae Sung Lee; Min-Hyun Park; Kyeong Min Kim; Seung-Ha Oh; Gi Jeong Cheon; In Chan Song; Dae Hyuk Moon; June-Key Chung; Dong Soo Lee
Journal:  Mol Imaging Biol       Date:  2009-12-01       Impact factor: 3.488

Review 2.  SPECT detectors: the Anger Camera and beyond.

Authors:  Todd E Peterson; Lars R Furenlid
Journal:  Phys Med Biol       Date:  2011-08-09       Impact factor: 3.609

3.  Monte Carlo Simulation Study on the Time Resolution of a PMT-Quadrant-Sharing LSO Detector Block for Time-of-Flight PET.

Authors:  Shitao Liu; Hongdi Li; Yuxuan Zhang; Rocio A Ramirez; Hossain Baghaei; Shaohui An; Chao Wang; Jiguo Liu; Wai-Hoi Wong
Journal:  IEEE Trans Nucl Sci       Date:  2009       Impact factor: 1.679

4.  Performance and limitations of positron emission tomography (PET) scanners for imaging very low activity sources.

Authors:  Melissa I Freedenberg; Ramsey D Badawi; Alice F Tarantal; Simon R Cherry
Journal:  Phys Med       Date:  2013-05-14       Impact factor: 2.685

5.  A CT-less approach to quantitative PET imaging using the LSO intrinsic radiation for long-axial FOV PET scanners.

Authors:  Mohammadreza Teimoorisichani; Vladimir Panin; Harold Rothfuss; Hasan Sari; Axel Rominger; Maurizio Conti
Journal:  Med Phys       Date:  2021-12-10       Impact factor: 4.506

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.