Literature DB >> 12388482

Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients.

Donald P Frush1, Christopher C Slack, Caroline L Hollingsworth, George S Bisset, Lane F Donnelly, Jiang Hsieh, Trudy Lavin-Wensell, John R Mayo.   

Abstract

OBJECTIVE: Limiting CT radiation dose is especially critical when imaging children. The purpose of our study was to modify and test an accurate and safe tool for evaluating systematic dose reduction for abdominal multidetector CT (MDCT) in pediatric patients.
MATERIALS AND METHODS: After validating the computer-simulation technique with a water phantom, we subjected the original digital scanning data for 26 contrast-enhanced abdominal MDCT scans (120 mA) obtained in infants and children (age range, 1 month-9 years; mean age, 3.1 years) to simulated tube current reduction (100, 80, 60, and 40 mA) by adding noise. this procedure created four additional examinations per child that were identical to the originals except for image noise. The 130 examinations were scored randomly, independently, and without prior knowledge of the children's diagnoses by three radiologists for depiction of high-visibility structures, such as adrenal glands and fat in the intrahepatic falciform ligament, and low-visibility structures, such as the extrahepatic hepatic artery, small intrahepatic vessels, and common bile duct. Aligned rank and Wilcoxon's signed rank tests were used for statistical analyses.
RESULTS: Simulated tube current reduction significantly affected the detection of low-visibility structures (p < 0.001). Reduced detection in low-visibility structures was evident at a level less than or equal to 80 mA. No loss of detection in high-visibility structures was found at any tube current level (p > 0.5).
CONCLUSION: The results of this computer simulation suggest that accurate abdominal MDCT can be performed in pediatric patients using substantially reduced radiation, depending on the indication for imaging. (In our case, the reduction was between 33% and 67%, depending on whether a high-visibility or low-visibility structure was being assessed.) This simulation technology can be applied to MDCT of other organ systems for systematic evaluation of radiation dose reduction.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12388482     DOI: 10.2214/ajr.179.5.1791107

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  40 in total

1.  Current status of low dose multi-detector CT in the urinary tract.

Authors:  Mi Kim Sung; Sarabjeet Singh; Mannudeep K Kalra
Journal:  World J Radiol       Date:  2011-11-28

2.  Reply to commentary--'CT radiation dose reduction: can we do harm by doing good?'.

Authors:  Beverley Newman; Michael J Callahan
Journal:  Pediatr Radiol       Date:  2012-04

3.  Review of a simple noise simulation technique in digital radiography.

Authors:  Rie Tanaka; Katsuhiro Ichikawa; Kosuke Matsubara; Hiroki Kawashima
Journal:  Radiol Phys Technol       Date:  2012-04-25

4.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

5.  Data analysis of low dose multislice helical CT scan in orbital trauma.

Authors:  Ji-Wei Wang; Chong Tang; Bo-Rong Pan
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

6.  A method to analyse observer disagreement in visual grading studies: example of assessed image quality in paediatric cerebral multidetector CT images.

Authors:  K Ledenius; E Svensson; F Stålhammar; L-M Wiklund; A Thilander-Klang
Journal:  Br J Radiol       Date:  2010-03-24       Impact factor: 3.039

7.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

8.  A computer simulation method for low-dose CT images by use of real high-dose images: a phantom study.

Authors:  Tomomi Takenaga; Shigehiko Katsuragawa; Makoto Goto; Masahiro Hatemura; Yoshikazu Uchiyama; Junji Shiraishi
Journal:  Radiol Phys Technol       Date:  2015-08-20

9.  A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation.

Authors:  Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Yoshiharu Nakayama; Da Liu; Taiga Goto; Yasuyuki Yamashita; Shinichi Hori
Journal:  Eur Radiol       Date:  2005-10-20       Impact factor: 5.315

10.  A technique for simulating the effect of dose reduction on image quality in digital chest radiography.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Jan Pieter A van Delft; Jacob Geleijns
Journal:  J Digit Imaging       Date:  2008-02-08       Impact factor: 4.056

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.