Literature DB >> 12378161

Characteristics of unsatisfactory shoulder arthroplasties.

Samer S Hasan1, Jordan M Leith, Barry Campbell, Ranjit Kapil, Kevin L Smith, Frederick A Matsen.   

Abstract

Failure of shoulder arthroplasty is often defined as a complication or the need for revision, but it may also be viewed as a result that does not meet the expectations of the patient. To enhance our understanding of failed shoulder arthroplasties, we identified the characteristics common to a series of 139 consecutive patients who came to our shoulder consultation service because of dissatisfaction with the result of their shoulder arthroplasty. Primary osteoarthritis (28%) and proximal humeral fractures (26%) were the most common indications for the initial arthroplasty. Seventy-three shoulders (fifty-two percent) had at least one surgery before arthroplasty was performed. Seventy-four percent of the shoulders were stiff, 35% were unstable, and in the total shoulders, 59% of the glenoids were loose. Components were substantially malpositioned in 23%. Forty-two percent of shoulders with a failed hemiarthroplasty had substantial glenoid erosion, and 43% of shoulders that had undergone a hemiarthroplasty for fracture had nonunion of the tuberosities. Patients demonstrated impaired shoulder function; on average, they could perform only 2 of 12 shoulder functions. The rate of revision underestimated the rate of failure, as 23% of arthroplasties did not undergo revision. The challenge of achieving patient satisfaction after arthroplasty may be greater than previously recognized. Many of these unsatisfactory shoulder arthroplasties did not meet the criteria for failure used in previously published series. These observations suggest that greater attention to achieving proper component position, postoperative motion, and in fracture cases, fixation of the tuberosities may lead to increased patient satisfaction after shoulder arthroplasty.

Entities:  

Mesh:

Year:  2002        PMID: 12378161     DOI: 10.1067/mse.2002.125806

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  60 in total

1.  Assessment of radiolucent lines in cemented shoulder hemi-arthroplasties: study of concordance and reproducibility.

Authors:  Carlos Torrens; Santos Martínez-Díaz; Aina Ruiz; Alberto Gines; Enrique Cáceres
Journal:  Int Orthop       Date:  2007-10-17       Impact factor: 3.075

2.  Incidence of risk in shoulder surgery : medical-legal repercussions.

Authors:  Mario Randelli; Leonardo Maradei; Nikolaos Markopoulos; Alessandro Castagna
Journal:  Chir Organi Mov       Date:  2008-03-03

3.  CT scan method accurately assesses humeral head retroversion.

Authors:  P Boileau; R T Bicknell; N Mazzoleni; G Walch; J P Urien
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

4.  [In situ assembly of a modular noncemented total shoulder prosthesis for the reconstruction of complex joint pathology].

Authors:  Beat R Simmen; Hans-Kaspar Schwyzer; Matthias P Flury; Jörg Goldhahn
Journal:  Oper Orthop Traumatol       Date:  2009-03       Impact factor: 1.154

5.  Soft tissue balancing in total shoulder replacement.

Authors:  Maike Mueller; Gregory Hoy
Journal:  Curr Rev Musculoskelet Med       Date:  2014-03

6.  [Survival rate and complications of stemmed shoulder prostheses in primary osteoarthritis].

Authors:  U Irlenbusch
Journal:  Orthopade       Date:  2013-07       Impact factor: 1.087

7.  Origin of propionibacterium in surgical wounds and evidence-based approach for culturing propionibacterium from surgical sites.

Authors:  Frederick A Matsen; Susan Butler-Wu; Bradley C Carofino; Jocelyn L Jette; Alexander Bertelsen; Roger Bumgarner
Journal:  J Bone Joint Surg Am       Date:  2013-12-04       Impact factor: 5.284

8.  Correlation between radiographic risk for glenoid component loosening and clinical scores in shoulder arthroplasty.

Authors:  Giovanni Merolla; Fabrizio Campi; Paolo Paladini; Nicola Lollino; Francesco Fauci; Giuseppe Porcellini
Journal:  Chir Organi Mov       Date:  2009-04

9.  Wear and damage of articular cartilage with friction against orthopedic implant materials.

Authors:  Sevan R Oungoulian; Krista M Durney; Brian K Jones; Christopher S Ahmad; Clark T Hung; Gerard A Ateshian
Journal:  J Biomech       Date:  2015-04-15       Impact factor: 2.712

10.  Intercellular adhesion molecule-1 (ICAM-1, CD54) is increased in adhesive capsulitis.

Authors:  Yang-Soo Kim; Jung-Man Kim; Yun-Gyoung Lee; Oak-Kee Hong; Hyuk-Sang Kwon; Jong-Hoon Ji
Journal:  J Bone Joint Surg Am       Date:  2013-02-20       Impact factor: 5.284

View more