Literature DB >> 12377869

Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.

Maura Prella1, François Feihl, Guido Domenighetti.   

Abstract

STUDY
OBJECTIVES: The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration.
DESIGN: Prospective, observational study.
SETTING: A multidisciplinary ICU in a nonuniversity, acute-care hospital. PATIENTS: Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years).
INTERVENTIONS: Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones.
RESULTS: PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p < 0.001; mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p < 0.05). The total mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p < 0.005).
CONCLUSIONS: These data show that PCV allows the generation of lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

Entities:  

Mesh:

Year:  2002        PMID: 12377869     DOI: 10.1378/chest.122.4.1382

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  33 in total

Review 1.  The design of future pediatric mechanical ventilation trials for acute lung injury.

Authors:  Robinder G Khemani; Christopher J L Newth
Journal:  Am J Respir Crit Care Med       Date:  2010-08-23       Impact factor: 21.405

2.  Pressure-controlled versus volume-controlled ventilation during one-lung ventilation in the prone position for robot-assisted esophagectomy.

Authors:  Yong Seon Choi; Jae Kwang Shim; Sungwon Na; Seung Bum Hong; Yong Woo Hong; Young Jun Oh
Journal:  Surg Endosc       Date:  2009-01-30       Impact factor: 4.584

3.  Linear model and algorithm to automatically estimate the pressure limit of pressure controlled ventilation for delivering a target tidal volume.

Authors:  Felice Eugenio Agrò; Paolo Cappa; Salvatore Andrea Sciuto; Sergio Silvestri
Journal:  J Clin Monit Comput       Date:  2006-03-06       Impact factor: 2.502

4.  Pressure-controlled versus volume-controlled ventilation during one-lung ventilation for video-assisted thoracoscopic lobectomy.

Authors:  Yi-Qi Zhu; Fang Fang; Xiao-Min Ling; Jian Huang; Jing Cang
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

5.  A novel adaptive control system for noisy pressure-controlled ventilation: a numerical simulation and bench test study.

Authors:  Alessandro Beda; Peter M Spieth; Thomas Handzsuj; Paolo Pelosi; Nadja C Carvalho; Edmund Koch; Thea Koch; Marcelo Gama de Abreu
Journal:  Intensive Care Med       Date:  2009-09-25       Impact factor: 17.440

6.  Comparison of two protective lung ventilatory regimes on oxygenation during one-lung ventilation: a randomized controlled trial.

Authors:  Félix R Montes; Daniel F Pardo; Hernán Charrís; Luis J Tellez; Juan C Garzón; Camilo Osorio
Journal:  J Cardiothorac Surg       Date:  2010-11-02       Impact factor: 1.637

7.  Comparison of intraoperative volume and pressure-controlled ventilation modes in patients who undergo open heart surgery.

Authors:  Tülay Hoşten; Alparslan Kuş; Esra Gümüş; Şadan Yavuz; Serhat İrkil; Mine Solak
Journal:  J Clin Monit Comput       Date:  2016-03-18       Impact factor: 2.502

Review 8.  Perioperative lung protective ventilation.

Authors:  Brian O'Gara; Daniel Talmor
Journal:  BMJ       Date:  2018-09-10

9.  Emergency department length of stay for patients requiring mechanical ventilation: a prospective observational study.

Authors:  Louise Rose; Sara Gray; Karen Burns; Clare Atzema; Alex Kiss; Andrew Worster; Damon C Scales; Gordon Rubenfeld; Jacques Lee
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-04-11       Impact factor: 2.953

10.  Comparison of volume-controlled and pressure-controlled ventilation using a laryngeal mask airway during gynecological laparoscopy.

Authors:  Woo Jae Jeon; Sang Yun Cho; Mi Rang Bang; So-Young Ko
Journal:  Korean J Anesthesiol       Date:  2011-03-30
View more