Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international codes of practice. International Atomic Energy Agency.

Pedro Andreo1, M Saiful Huq, Mathias Westermark, Haijun Song, Aris Tilikidis, Larry DeWerd, Ken Shortt.   

Abstract

A new international Code of Practice for radiotherapy dosimetry co-sponsored by several international organizations has been published by the IAEA, TRS-398. It is based on standards of absorbed dose to water, whereas previous protocols (TRS-381 and TRS-277) were based on air kerma standards. To estimate the changes in beam calibration caused by the introduction of TRS-398, a detailed experimental comparison of the dose determination in reference conditions in high-energy photon and electron beams has been made using the different IAEA protocols. A summary of the formulation and reference conditions in the various Codes of Practice, as well as of their basic data, is presented first. Accurate measurements have been made in 25 photon and electron beams from 10 clinical accelerators using 12 different cylindrical and plane-parallel chambers, and dose ratios under different conditions of TRS-398 to the other protocols determined. A strict step-by-step checklist was followed by the two participating clinical institutions to ascertain that the resulting calculations agreed within tenths of a per cent. The maximum differences found between TRS-398 and the previous Codes of Practice TRS-277 (2nd edn) and TRS-381 are of the order of 1.5-2.0%. TRS-398 yields absorbed doses larger than the previous protocols, around 1.0% for photons (TRS-277) and for electrons (TRS-381 and TRS-277) when plane-parallel chambers are cross-calibrated. For the Markus chamber, results show a very large variation, although a fortuitous cancellation of the old stopping powers with the ND,w/NK ratios makes the overall discrepancy between TRS-398 and TRS-277 in this case smaller than for well-guarded plane-parallel chambers. Chambers of the Roos-type with a 60Co ND,w calibration yield the maximum discrepancy in absorbed dose, which varies between 1.0% and 1.5% for TRS-381 and between 1.5% and 2.0% for TRS-277. Photon beam calibrations using directly measured or calculated TPR20,10 from a percentage dose data at SSD = 100 cm were found to be indistinguishable. Considering that approximately 0.8% of the differences between TRS-398 and the NK-based protocols are caused by the change to the new type of standards, the remaining difference in absolute dose is due either to a close similarity in basic data or to a fortuitous cancellation of the discrepancies in data and type of chamber calibration. It is emphasized that the NK-ND,air and ND,w formalisms have very similar uncertainty when the same criteria are used for both procedures. Arguments are provided in support of the recommendation for a change in reference dosimetry based on standards of absorbed dose to water.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12361209     DOI: 10.1088/0031-9155/47/17/301

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Direct megavoltage photon calibration service in Australia.

Authors:  D J Butler; G Ramanathan; C Oliver; A Cole; J Lye; P D Harty; T Wright; D V Webb; D S Followill
Journal:  Australas Phys Eng Sci Med       Date:  2014-08-22       Impact factor: 1.430

2.  Quantifying the influences of radiation therapy on deformability of human red blood cells by dual-beam optical tweezers.

Authors:  Medine Tuna Inanc; Irem Demirkan; Cemile Ceylan; Alper Ozkan; Ozcan Gundogdu; Utku Goreke; Umut A Gurkan; Mehmet Burcin Unlu
Journal:  RSC Adv       Date:  2021-04-27       Impact factor: 4.036

3.  Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.

Authors:  Mansour Almurayshid; Yusuf Helo; Andrzej Kacperek; Jennifer Griffiths; Jem Hebden; Adam Gibson
Journal:  J Appl Clin Med Phys       Date:  2017-07-29       Impact factor: 2.102

4.  "Characterization of ELEKTA SRS cone collimator using high spatial resolution monolithic silicon detector array".

Authors:  Khalsa Al Shukaili; Stéphanie Corde; Marco Petasecca; Vladimir Pereveratylo; Michael Lerch; Michael Jackson; Anatoly Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2018-05-22       Impact factor: 2.102

5.  Absolute dose determination in high-energy electron beams: Comparison of IAEA dosimetry protocols.

Authors:  S Sathiyan; M Ravikumar
Journal:  J Med Phys       Date:  2008-07

6.  Solid water phantom heat conduction: Heating and cooling rates.

Authors:  Martin J Butson; Tsang Cheung; Peter K N Yu
Journal:  J Med Phys       Date:  2008-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.