Literature DB >> 12361161

Higher order aberrations in normal, dilated, intraocular lens, and laser in situ keratomileusis corneas.

Joseph M Miller1, Raana Anwaruddin, Jochen Straub, Jim Schwiegerling.   

Abstract

PURPOSE: To compare repeated measures of Zernike polynomial higher-order aberrations in 29 normal, 13 dilated normal, 11 intraocular lens (IOL), 11 laser in situ keratomileusis (LASIK), and one refractive keratectomy (RK)/IOL subject.
METHODS: At least three Shack-Hartmann images were obtained from each subject, and higher order (uncorrectable by spectacles) Zernike representation was determined. For each subject, confidence intervals for each Zernike coefficient were determined as a function of pupil size. Significant (P<.05) coefficients were averaged within groups, and group means were compared to normal subjects.
RESULTS: No differences were seen between the normal and dilated groups at P=.05. The patients with prior LASIK and IOL surgery showed statistically significant elevation of 4th order spherical aberration and total wavefront variance for pupil sizes greater than 5 mm, compared to normals.
CONCLUSION: Both IOL and LASIK surgery elevate spherical aberration and wavefront variance, with increasing magnitude of effect with increasing pupil size, although pupillary dilation alone did not produce statistically different changes, as compared to normal subjects. These findings demonstrate that IOL implantation can produce more net aberrations than LASIK, and demonstrate a new opportunity to optimize surgical results.

Entities:  

Mesh:

Year:  2002        PMID: 12361161     DOI: 10.3928/1081-597X-20020901-16

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  14 in total

1.  Comparison of higher-order aberration and optical quality after Epi-LASIK and LASIK for myopia.

Authors:  Xiaoyan Yang; Yan Wang; Kanxing Zhao; Lihua Fang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-05-07       Impact factor: 3.117

2.  Effects of reference axes used during measurements of ocular and corneal higher-order aberrations in patients following LASIK.

Authors:  Atsuko Takehara; Naoyuki Maeda; Sayuri Ninomiya; Takashi Fujikado; Yoko Hiroha; Toshifumi Mihashi
Journal:  Jpn J Ophthalmol       Date:  2006 Jul-Aug       Impact factor: 2.447

3.  Influence of across-pupil sutures on the optical quality of intraocular lenses.

Authors:  Chang Rae Rho; Min-Ji Kim; Choun-Ki Joo
Journal:  Int Ophthalmol       Date:  2017-02-04       Impact factor: 2.031

4.  Method for expressing clinical and statistical significance of ocular and corneal wave front error aberrations.

Authors:  Michael K Smolek
Journal:  Cornea       Date:  2012-03       Impact factor: 2.651

5.  Peripheral aberrations and image quality for contact lens correction.

Authors:  Jie Shen; Larry N Thibos
Journal:  Optom Vis Sci       Date:  2011-10       Impact factor: 1.973

6.  Comparison of high order aberration after conventional and customized ablation in myopic LASIK in different eyes of the same patient.

Authors:  Chi-xin Du; Ye Shen; Yang Wang
Journal:  J Zhejiang Univ Sci B       Date:  2007-03       Impact factor: 3.066

7.  Ocular wavefront aberrations in patients with macular diseases.

Authors:  Kenichiro Bessho; Dirk-Uwe G Bartsch; Laura Gomez; Lingyun Cheng; Hyoung Jun Koh; William R Freeman
Journal:  Retina       Date:  2009-10       Impact factor: 4.256

8.  The association between femtosecond laser flap parameters and ocular aberrations after uncomplicated custom myopic LASIK.

Authors:  Christopher T Hood; Ronald R Krueger; Steven E Wilson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-04-09       Impact factor: 3.117

Review 9.  Adaptive optics technology for high-resolution retinal imaging.

Authors:  Marco Lombardo; Sebastiano Serrao; Nicholas Devaney; Mariacristina Parravano; Giuseppe Lombardo
Journal:  Sensors (Basel)       Date:  2012-12-27       Impact factor: 3.576

10.  Variability of wavefront aberration measurements in small pupil sizes using a clinical Shack-Hartmann aberrometer.

Authors:  Harilaos S Ginis; Sotiris Plainis; Aristophanis Pallikaris
Journal:  BMC Ophthalmol       Date:  2004-02-11       Impact factor: 2.209