Literature DB >> 23714089

Electrocardiographic algorithm for the diagnosis of inadvertent implantation of permanent pacemaker lead in the left ventricular cavity.

Gustavo Goldenberg1, Zaza Iakobishvili, Boris Strasberg.   

Abstract

Inadvertent placement of a pacemaker lead electrode in the left ventricle is an unusual complication and the electrocardiogram is a useful tool for the diagnoses. We present such a patient and review the electrocardiographic characteristics that should raise such a possibility. ©2012, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23714089      PMCID: PMC6932113          DOI: 10.1111/anec.12021

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  5 in total

1.  Seven years of left ventricular pacing due to malposition of pacing electrode.

Authors:  H Shmuely; S Erdman; B Strasberg; J B Rosenfeld
Journal:  Pacing Clin Electrophysiol       Date:  1992-04       Impact factor: 1.976

2.  An electrocardiographic algorithm for determining the location of pacemaker electrode in patients with right bundle branch block configuration during permanent ventricular pacing.

Authors:  Ertan Okmen; Izzet Erdinler; Enis Oguz; Ahmet Akyol; Onur Turek; Nese Cam; Tanju Ulufer
Journal:  Angiology       Date:  2006 Oct-Nov       Impact factor: 3.619

3.  Asymptomatic left ventricular malposition of a transvenous pacemaker lead through a sinus venosus defect: follow-up over 17 years.

Authors:  F Van Erckelens; M Sigmund; H Lambertz; A Kreis; C Reupcke; P Hanrath
Journal:  Pacing Clin Electrophysiol       Date:  1991-06       Impact factor: 1.976

4.  Unusual QRS morphology associated with transvenous pacemakers. The pseudo RBBB pattern.

Authors:  H O Klein; B Beker; P Sareli; E DiSegni; H Dean; E Kaplinsky
Journal:  Chest       Date:  1985-04       Impact factor: 9.410

5.  Delayed complications following pacemaker implantation.

Authors:  Kenneth A Ellenbogen; Mark A Wood; Richard K Shepard
Journal:  Pacing Clin Electrophysiol       Date:  2002-08       Impact factor: 1.976

  5 in total
  2 in total

1.  Inadvertent placement of pacemaker lead into the middle cardiac vein.

Authors:  S Topaloglu; F Bayraktar; S Okten; S Cetin; O Ozeke; S Cay; D Aras
Journal:  Herz       Date:  2014-07-19       Impact factor: 1.443

Review 2.  From lysosome to proteasome: the power of yeast in the dissection of proteinase function in cellular regulation and waste disposal.

Authors:  D H Wolf
Journal:  Cell Mol Life Sci       Date:  2004-07       Impact factor: 9.261

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.