Literature DB >> 12358108

Robotically-milled bone cavities: a comparison with hand-broaching in different types of cementless hip stems.

Marc N Thomsen1, Steffen J Breusch, Peter R Aldinger, Wolfgang Görtz, Andreas Lahmer, Mathias Honl, Andreas Birke, Hans Nägerl.   

Abstract

We performed an experimental study to compare the effectiveness of robotic bone milling (Robodoc and CASPAR) with hand-broaching as regards primary rotational stability of 7 different cementless stems. Using 48 synthetic femora and a specially-designed apparatus, we compared the implant stability of proximal and distal rotational stem displacement (slip) in relation to the cortex. We also measured stem deformation (twist) and the location of torque transfer from stem to cortex (i.e., fixation pattern). 5-ROM, Antega, and ABG stems were more stable in hand-broached femora. Osteolock stems showed no difference between CASPAR and hand preparation, but rotational stability was better in the Robodoc group. G2, VerSys ET and Vision 2000 stems gave increased rotational stability in the robotic groups. When placed too laterally, Vision 2000 showed a pattern of more distal fixation. The findings emphasize the current difficulties in creating a perfect match of robotically-milled cavity and stem geometry to achieve enhanced primary rotational stability. The pattern of fixation seems to depend not only on stem design, but also on canal preparation and stem positioning.

Mesh:

Year:  2002        PMID: 12358108     DOI: 10.1080/00016470216317

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  4 in total

1.  New aspects and approaches in pre-operative planning of hip reconstruction: a computer simulation.

Authors:  Marco Viceconti; Alessandro Chiarini; Debora Testi; Fulvia Taddei; Barbara Bordini; Francesco Traina; Aldo Toni
Journal:  Langenbecks Arch Surg       Date:  2004-01-15       Impact factor: 3.445

2.  The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty.

Authors:  Li-dong Wu; H J Hahne; J Hassenpflug
Journal:  J Zhejiang Univ Sci       Date:  2004-10

3.  Robot-assisted fracture reduction: a preliminary study in the femur shaft.

Authors:  T Gosling; R Westphal; T Hufner; J Faulstich; M Kfuri; F Wahl; C Krettek
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

Review 4.  Computer-assisted orthopaedic surgery and robotic surgery in total hip arthroplasty.

Authors:  Nobuhiko Sugano
Journal:  Clin Orthop Surg       Date:  2013-02-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.