Literature DB >> 12324798

Contrast perception in digitized panoramic radiographs compared with their film-based origin.

Ralf Kurt Willy Schulze1, Stephan Tobias Roman Rosing, Bernd D'Hoedt.   

Abstract

OBJECTIVES: We sought to compare the visual image quality of film-based and digitized panoramic radiographs through use of a hole-containing test wedge. STUDY
DESIGN: An aluminum wedge containing 100 cells, of which 90 were given shallow holes, was exposed in the film-based Orthophos CD panoramic unit. Two radiographs subjectively exhibiting optimum contrast were selected. Films were digitized with a charge-coupled device flatbed scanner at 300 dpi. Films and digitized images were rated cellwise by 2 similar groups of 50 observers each with respect to spot perception.
RESULTS: The mean sensitivity was 0.26 +/- 0.09 for film and 0.20 +/- 0.07 for digitized images (P =.000), with a pronounced decline in the latter in regions of high background density. The average specificity was 0.93 +/- 0.07 for film versus 0.92 +/- 0.08 for digitized images (P = 0.213).
CONCLUSION: Film yielded a significantly higher sensitivity, but this absolute difference was actually small compared with that of the digitized images.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12324798     DOI: 10.1067/moe.2002.126450

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  4 in total

1.  Quantitative pixel grey measurement of the "high-risk" sign, darkening of third molar roots: a pilot study.

Authors:  J Szalma; Z Bata; E Lempel; S Jeges; L Olasz
Journal:  Dentomaxillofac Radiol       Date:  2013-06-17       Impact factor: 2.419

2.  Annual bone loss and success rates of dental implants based on radiographic measurements.

Authors:  W Geraets; L Zhang; Y Liu; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2014-07-17       Impact factor: 2.419

3.  Evaluating noise in digitized radiographic images by means of histogram.

Authors:  Izabel Regina Fischer Rubira-Bullen; Maurício Cunha Escarpinati; Homero Schiabel; Marcelo Andrade da Costa Vieira; Cássia Maria Fischer Rubira; José Roberto Pereira Lauris
Journal:  J Appl Oral Sci       Date:  2006-12       Impact factor: 2.698

4.  Digitizing radiographic films: a simple way to evaluate indirect digital images.

Authors:  Izabel Regina Fischer Rubia-Bullen; Maurício Cunha Escarpinati; Homero Schiabel; Marcelo Andrade da Costa Vieira; Cássia Maria Fischer Rubira; José Roberto Pereira Lauris
Journal:  J Appl Oral Sci       Date:  2007-02       Impact factor: 2.698

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.