Literature DB >> 12297162

A four-dimensional study of the aortic root dynamics.

E Lansac1, H S Lim, Y Shomura, K H Lim, N T Rice, W Goetz, C Acar, C M G Duran.   

Abstract

OBJECTIVE: Although aortic root expansion has been well studied, its deformation and physiologic relevance remain controversial. Three-dimensional (3-D) sonomicrometry (200Hz) has made time-related 4-D study possible.
METHODS: Fifteen sonomicrometric crystals were implanted into the aortic root of eight sheep at each base (three), commissures (three), sinuses of Valsalva (three), sinotubular junction (three), and ascending aorta (three). In this acute, open-chest model, the aortic root geometric deformations were time related to left ventricular and aortic pressures.
RESULTS: During the cardiac cycle, aortic root volume increased by mean+/-1 standard error of the mean (SEM) 33.7+/-2.7%, with 36.7+/-3.3% occurring prior to ejection. Expansion started during isovolumic contraction at the base and commissures followed (after a delay) by the sinotubular junction. At the same time, ascending aorta area decreased (-2.6+/-0.4%). During the first third of ejection, the aortic root reached maximal expansion followed by a slow, then late rapid decrease in volume until mid-diastole. During end-diastole, the aortic root volume re-expanded by 11.3+/-2.4%, but with different dynamics at each area level. Although the base and commissural areas re-expanded, the sinotubular junction and ascending aorta areas kept decreasing. At end-diastole, the aortic root had a truncated cone shape (base area>commissures area by 51.6+/-2.0%). During systole, the root became more cylindrical (base area>commissures area by 39.2+/-2.5%) because most of the significant changes occurred at commissural level (63.7+/-3.6%).
CONCLUSION: Aortic root expansion follows a precise chronology during systole and becomes more cylindrical - probably to maximize ejection. These findings might stimulate a more physiologic approach to aortic valve and aortic root surgical procedures.

Entities:  

Mesh:

Year:  2002        PMID: 12297162     DOI: 10.1016/s1010-7940(02)00405-0

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  22 in total

1.  Validation of three-dimensional echocardiography for quantification of aortic root geometry: comparison with multi-detector computed tomography.

Authors:  Jin-Sun Park; Yong-Woo Choi; Jeoung-Sook Shin; Hyoung-Mo Yang; Hong-Seok Lim; Byoung-Joo Choi; So-Yeon Choi; Myeong-Ho Yoon; Gyo-Seung Hwang; Seung-Jea Tahk; Joon-Han Shin
Journal:  J Cardiovasc Ultrasound       Date:  2011-09-30

Review 2.  The left ventricular outflow in hypertrophic cardiomyopathy: from structure to function.

Authors:  Magdi H Yacoub; Ismail El-Hamamsy; Karim Said; Gehan Magdi; Fatma Abul Enein; Robert George; Alessandra Rossi; Iacopo Olivotto; Franco Cecchi
Journal:  J Cardiovasc Transl Res       Date:  2009-11-26       Impact factor: 4.132

3.  Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole.

Authors:  Angela G Bertaso; Dennis T L Wong; Gary Y H Liew; Michael S Cunnington; James D Richardson; Viji S Thomson; Brett Lorraine; George Kourlis; Diana Leech; Matthew I Worthley; Stephen G Worthley
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-09       Impact factor: 2.357

Review 4.  Aortic root dynamics and surgery: from craft to science.

Authors:  Allen Cheng; Paul Dagum; D Craig Miller
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

5.  Anatomy and pathophysiology of the ventriculo-aortic junction: implication in aortic valve repair surgery.

Authors:  Laurent de Kerchove; Gebrine El Khoury
Journal:  Ann Cardiothorac Surg       Date:  2013-01

Review 6.  In vivo imaging and computational analysis of the aortic root. Application in clinical research and design of transcatheter aortic valve systems.

Authors:  Paul Schoenhagen; Alexander Hill; Tim Kelley; Zoran Popovic; Sandra S Halliburton
Journal:  J Cardiovasc Transl Res       Date:  2011-04-12       Impact factor: 4.132

7.  Comparison of radial deformability of stent posts of different aortic bioprostheses.

Authors:  Martins Kalejs; Romans Lacis; Vladimir Kasyanov; Iveta Ozolanta; Philippe Abdel Sayed; Peteris Stradins; Ludwig Karl von Segesser
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-11-01

8.  Aortic annulus and the importance of annuloplasty.

Authors:  Pouya Youssefi; Emmanuel Lansac
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-10-07

9.  Abnormal mitral-aortic intervalvular coupling in mitral valve diseases: a study using real-time three-dimensional transesophageal echocardiography.

Authors:  Jen-Li Looi; Alex Pui-Wai Lee; Fang Fang; Ming C Hsiung; Jing-Ping Sun; Wei-Hsian Yin; Jeng Wei; Shen-Kou Tsai; Song Wan; Randolph Hl Wong; Malcolm J Underwood; Qing-Shan Lin; Chun-Na Jin; Liu Chen; Cheuk-Man Yu
Journal:  Clin Res Cardiol       Date:  2015-04-09       Impact factor: 5.460

10.  Immersed boundary-finite element model of fluid-structure interaction in the aortic root.

Authors:  Vittoria Flamini; Abe DeAnda; Boyce E Griffith
Journal:  Theor Comput Fluid Dyn       Date:  2015-12-19       Impact factor: 1.606

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.