Literature DB >> 12271366

Efficiency of a video-autorefractometer used as a screening device for amblyogenic factors.

Thilo Schimitzek1, Wolfgang Haase.   

Abstract

BACKGROUND: High ametropia is known as a risk factor in developing amblyopia. The aim of the study was to evaluate the efficiency of a commercially available infrared videorefractometer (PowerRefractor) in examining children, and to evaluate its effectiveness in detecting amblyogenic factors of the refraction. The influence of cycloplegia was of interest.
METHODS: A total of 255 eyes (-28.25 D to +7.88 D spherical equivalent) of 128 patients (1-81 years) were examined by cycloplegic retinoscopy. All of them were measured with the PowerRefractor under cycloplegia. Fifty-four of these patients (108 eyes) were additionally measured without cycloplegia. The technique of the device is based on the eccentric photorefraction method. Both eyes can be measured simultaneously from a distance of 1 m. A video-analysis of each eye is computed in three meridians. The subject can be observed in real time on a screen, and the refraction is immediately available.
RESULTS: Measurement of refraction was possible at all ages. More effort was required with young children who could not cooperate well with the procedure of conventional table-top autorefractometers. The mean sensitivity in detection of any amblyogenic ametropia was 80% with and without cycloplegia. The specificity was 61% with cycloplegia and 84% without. The rate of false-negative results in the detection of anisometropia, hyperopia and astigmatism ranged from 10% to 24%. In particular, high astigmatism and hyperopia remained undiscovered.
CONCLUSIONS: The reliability of the photorefractor which was the subject of the evaluation in detecting amblyogenic ametropia was comparable to that of other devices described previously in the literature. The method is suitable for use in children, but anisometropia, high astigmatic and hyperopic ametropia remained undiscovered in several cases. Commercial interest: none.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12271366     DOI: 10.1007/s00417-002-0524-5

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  19 in total

1.  Two-dimensional simulation of eccentric photorefraction images for ametropes: factors influencing the measurement.

Authors:  Yifei Wu; Larry N Thibos; T Rowan Candy
Journal:  Ophthalmic Physiol Opt       Date:  2018-05-07       Impact factor: 3.117

2.  Human infants' accommodation responses to dynamic stimuli.

Authors:  Grazyna M Tondel; T Rowan Candy
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-02       Impact factor: 4.799

3.  Comparison of non-cycloplegic photorefraction, cycloplegic photorefraction and cycloplegic retinoscopy in children.

Authors:  Ozdemir Ozdemir; Zuhal Özen Tunay; Ikbal Seza Petriçli; Damla Ergintürk Acar; Muhammet Kazım Erol
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

4.  Accuracy of a new photo-refractometer in young and adult patients.

Authors:  Thilo Schimitzek; Wolf A Lagrèze
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-01-14       Impact factor: 3.117

5.  Validation of the PowerRefractor for measuring human infant refraction.

Authors:  Pamela J Blade; T Rowan Candy
Journal:  Optom Vis Sci       Date:  2006-06       Impact factor: 1.973

6.  The relationship between anisometropia, patient age, and the development of amblyopia.

Authors:  Sean P Donahue
Journal:  Trans Am Ophthalmol Soc       Date:  2005

7.  Is noncycloplegic photorefraction applicable for screening refractive amblyopia risk factors?

Authors:  Zhale Rajavi; Hiva Parsafar; Alireza Ramezani; Mehdi Yaseri
Journal:  J Ophthalmic Vis Res       Date:  2012-01

8.  Prevalence of Color Vision Deficiency and its Correlation with Amblyopia and Refractive Errors among Primary School Children.

Authors:  Zhale Rajavi; Hamideh Sabbaghi; Ahmad Shojaei Baghini; Mehdi Yaseri; Koroush Sheibani; Ghazal Norouzi
Journal:  J Ophthalmic Vis Res       Date:  2015 Apr-Jun

9.  Prevalence of Amblyopia and Refractive Errors Among Primary School Children.

Authors:  Zhale Rajavi; Hamideh Sabbaghi; Ahmad Shojaei Baghini; Mehdi Yaseri; Hamidreza Moein; Shadi Akbarian; Narges Behradfar; Simin Hosseini; Hossein Mohammad Rabei; Kourosh Sheibani
Journal:  J Ophthalmic Vis Res       Date:  2015 Oct-Dec

10.  Evaluation of 'vision screening' program for three to six-year-old children in the Republic of Iran.

Authors:  Rajiv Khandekar; Noa Parast; Ashraf Arabi
Journal:  Indian J Ophthalmol       Date:  2009 Nov-Dec       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.