Literature DB >> 12238424

Choice of device size and results of transcatheter closure of atrial septal defect using the amplatzer septal occluder.

Zhong-Dong Du1, Qi-Ling Cao, Jonathan Rhodes, Mary Heitschmidt, Ziyad M Hijazi.   

Abstract

The impact of device size choice on closure results was analyzed in 138 (101 females, 37 males; age 0.5-84.0 years) consecutive patients who underwent transcatheter closure of the secundum atrial septal defect (ASD) using the Amplatzer septal occluder (ASO). The balloon stretched diameter (SD) of ASD was 19.5 +/- 7.2 mm in 123 patients with single defects, and 20.4 +/- 6.6 mm for the largest defects in 15 patients with multiple ASDs. The difference (delta) between ASO size chosen for closure and the stretched diameter of the defect was calculated and divided into groups: A (delta < -2 mm); B (delta -2.0 to -0.1 mm); C (delta = 0); D (delta 0.1-2.0 mm) and E (delta > 2 mm). The results demonstrated that immediate and 24-hour complete closure rates were significantly higher in patients in groups C and D (P < 0.001). However, at 6-month follow-up, the complete closure rates were similar in patients of groups A-D, while patients of group E had a lower closure rate of 75%. The complication rates were similar in all groups. In conclusion, a choice of a device size identical to or within 2 mm larger than the SD of the defect should be used to maximize the closure rates of ASD using the ASO.

Entities:  

Mesh:

Year:  2002        PMID: 12238424     DOI: 10.1111/j.1540-8183.2002.tb01105.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  10 in total

1.  Cor triatriatum dexter and atrial septal defect in a 43-year-old woman.

Authors:  Petar M Vukovic; Dragana Kosevic; Miroslav Milicic; Ljiljana Jovovic; Ivan Stojanovic; Slobodan Micovic
Journal:  Tex Heart Inst J       Date:  2014-08-01

Review 2.  Challenges encountered during closure of atrial septal defects.

Authors:  W Knirsch; A Dodge-Khatami; E Valsangiacomo-Buechel; M Weiss; F Berger
Journal:  Pediatr Cardiol       Date:  2005 Mar-Apr       Impact factor: 1.655

3.  Assessment of atrial septal defects in adults comparing cardiovascular magnetic resonance with transoesophageal echocardiography.

Authors:  Karen S L Teo; Patrick J Disney; Benjamin K Dundon; Matthew I Worthley; Michael A Brown; Prashanthan Sanders; Stephen G Worthley
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-22       Impact factor: 5.364

4.  Community use of the amplatzer atrial septal defect occluder: results of the multicenter MAGIC atrial septal defect study.

Authors:  Allen D Everett; Jacky Jennings; Erica Sibinga; Carl Owada; D Scott Lim; John Cheatham; Ralf Holzer; Jeremy Ringewald; Rani Bandisode; Richard Ringel
Journal:  Pediatr Cardiol       Date:  2008-11-18       Impact factor: 1.655

5.  Appropriate selection of echocardiographic guidance for transcatheter atrial septal defect closure.

Authors:  Michiyo Yamano; Tetsuhiro Yamano; Takeshi Nakamura; Kan Zen; Hirokazu Shiraishi; Takeshi Shirayama; Satoaki Matoba
Journal:  Int J Cardiovasc Imaging       Date:  2020-02-10       Impact factor: 2.357

6.  Intermediate and long-term followup of percutaneous device closure of fossa ovalis atrial septal defect by the Amplatzer septal occluder in a cohort of 529 patients.

Authors:  Munesh Tomar; Sanjay Khatri; Sitaraman Radhakrishnan; Savitri Shrivastava
Journal:  Ann Pediatr Cardiol       Date:  2011-01

7.  Trans-catheter closure of atrial septal defect: Balloon sizing or no Balloon sizing - single centre experience.

Authors:  Saurabh Kumar Gupta; S Sivasankaran; S Bijulal; Jagan Mohan Tharakan; S Harikrishnan; Kvk Ajit
Journal:  Ann Pediatr Cardiol       Date:  2011-01

8.  Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect.

Authors:  Semi Ozturk; Ahmed Seyfettin Gurbuz; Suleyman Cagan Efe; Mehmet Fatih Yılmaz; Cevat Kırma
Journal:  Korean Circ J       Date:  2017-09-11       Impact factor: 3.243

9.  Transcatheter Atrial Septal Defect Closure in Children with and without Fluoroscopy: A Comparison.

Authors:  S Ackermann; D Quandt; N Hagenbuch; O Niesse; M Christmann; W Knirsch; O Kretschmar
Journal:  J Interv Cardiol       Date:  2019-04-07       Impact factor: 2.279

10.  A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect.

Authors:  Alimohammad Hajizeinali; Hakimeh Sadeghian; Mehrnaz Rezvanfard; Mohammad Alidoosti; Arezoo Zoroufian; Marat A Volman
Journal:  Cardiovasc J Afr       Date:  2013-06       Impact factor: 1.167

  10 in total