The use of a reflective scanner to study radiochromic film response.

H Alva1, H Mercado-Uribe, M Rodríguez-Villafuerte, M E Brandan.   

Abstract

GafChromic MD-55-2 film response was studied using a flatbed, reflective Microtek ScanMaker E3 scanner, under different conditions to optimize its use. Irradiations were performed using 60Co gamma rays in a 0-300 Gy dose interval to produce a calibrated step wedge. A 24-bit colour-scale mode along with image splitting into its red, green and blue components is suggested as an improved dosimetry method over a 256 grey level (8-bit) mode, extending the dynamic range for this film. Diverse film orientation and positioning, a black or a white background, and individual step film scanning were evaluated. Unwanted normalization is overcome by adding reference black and white steps adjacent to the radiochromic film, ensuring reproducibility. The use of a red filter was found to be equivalent to the use of the red component of the image after image colour splitting. The useful range for MD-55-2 film is extended up to 300 Gy if colour components, other than red, are used to evaluate the response. Comparisons with optical density measurements show that inexpensive commercial scanners might be a good alternative to densitometers.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12222856     DOI: 10.1088/0031-9155/47/16/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures.

Authors:  Samuel Brady; Terry Yoshizumi; Greta Toncheva; Donald Frus
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Absorbed dose and transmission factor in blocked fields for radiotherapy treatments with 6 MV X-ray.

Authors:  Ana Elena Buenfil; Marvin Francisco Rodríguez-González; Gabriel Reséndiz González; María Ester Brandan
Journal:  Clin Transl Oncol       Date:  2006-04       Impact factor: 3.405

3.  Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner.

Authors:  Bradley P McCabe; Michael A Speidel; Tina L Pike; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

Authors:  Dominic J Crotty; Samuel L Brady; D'Vone C Jackson; Greta I Toncheva; Colin E Anderson; Terry T Yoshizumi; Martin P Tornai
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

6.  A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.

Authors:  Samuel L Brady; Rathnayaka Gunasingha; Terry T Yoshizumi; Calvin R Howell; Alexander S Crowell; Brent Fallin; Anton P Tonchev; Mark W Dewhirst
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

7.  Application of a color scanner for (60)Co high dose rate brachytherapy dosimetry with EBT radiochromic film.

Authors:  Mahdi Ghorbani; Mohammad Taghi Bahreyni Toossi; Ali Asghar Mowlavi; Shahram Bayani Roodi; Ali Soleimani Meigooni
Journal:  Radiol Oncol       Date:  2012-11-09       Impact factor: 2.991

8.  Spatial dose distributions in solid tumors from 186Re transported by liposomes using HS radiochromic media.

Authors:  Luis A Medina; Beth Goins; Mercedes Rodríguez-Villafuerte; Ande Bao; Arnulfo Martínez-Davalos; Vibhudutta Awasthi; Olga O Galván; Cristina Santoyo; William T Phillips; María-Ester Brandan
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057

9.  Use of an orthovoltage X-ray treatment unit as a radiation research system in a small-animal cancer model.

Authors:  Luis-Alberto Medina; Blanca-Ivone Herrera-Penilla; Mario-Alberto Castro-Morales; Patricia García-López; Rafael Jurado; Enrique Pérez-Cárdenas; José Chanona-Vilchis; María-Ester Brandan
Journal:  J Exp Clin Cancer Res       Date:  2008-10-28

10.  Dose evaluation for skin and organ in hepatocellular carcinoma during angiographic procedure.

Authors:  Daniela D'Alessio; Claudia Giliberti; Antonella Soriani; Livio Carpanese; Giuseppe Pizzi; Giulio Vallati; Lidia Strigari
Journal:  J Exp Clin Cancer Res       Date:  2013-10-25