Model-based oscillometric blood pressure measurement: preliminary validation in humans.

Jiankun Liu, Hao-min Cheng, Chen-Huan Chen, Shih-Hsien Sung, Jin-Oh Hahn, Ramakrishna Mukkamala.   

Abstract

We conceived new oscillometric blood pressure (BP) estimation methods based on physical modeling. The crux of these methods is to simultaneously estimate the arterial stiffness and BP of the patient from a standard oscillometric waveform. Hence, in contrast to previous methods, the BP estimation is specific to the span>n class="Species">patient at the time of measurement and is robust against arterial stiffening. We conducted initial testing of one of the methods against invasive reference brachial BP measurements in eight cardiac catheterization patients before and after nitroglycerin infusions. The method achieved systolic, diastolic and mean BP root-mean-squared-errors of 7.2, 7.6 and 6.7 mmHg. These errors were, on average, 40% lower than an existing high-end method.

Entities:  

Mesh:

Year:  2014        PMID: 25570365      PMCID: PMC4530961          DOI: 10.1109/EMBC.2014.6943997

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  8 in total

1.  Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia.

Authors:  P Natarajan; A H Shennan; J Penny; A W Halligan; M de Swiet; J Anthony
Journal:  Am J Obstet Gynecol       Date:  1999-11       Impact factor: 8.661

2.  An initial step towards improving the accuracy of the oscillometric blood pressure measurement.

Authors:  Jiankun Liu; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

3.  Accuracy of an automated blood pressure device in stable inpatients: optimum vs routine use.

Authors:  C L Shuler; N Allison; S Holcomb; M Harlan; J McNeill; G Robinett; S P Bagby
Journal:  Arch Intern Med       Date:  1998-04-13

4.  Theory of the oscillometric maximum and the systolic and diastolic detection ratios.

Authors:  G Drzewiecki; R Hood; H Apple
Journal:  Ann Biomed Eng       Date:  1994 Jan-Feb       Impact factor: 3.934

5.  Characterization of the oscillometric method for measuring indirect blood pressure.

Authors:  L A Geddes; M Voelz; C Combs; D Reiner; C F Babbs
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

6.  Comparison of two generalized transfer functions for measuring central systolic blood pressure by an oscillometric blood pressure monitor.

Authors:  Y-T Shih; H-M Cheng; S-H Sung; W-C Hu; C-H Chen
Journal:  J Hum Hypertens       Date:  2012-05-03       Impact factor: 3.012

7.  A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor.

Authors:  Samuel A Mireles; Richard A Jaffe; David R Drover; John G Brock-Utne
Journal:  J Clin Monit Comput       Date:  2009-04-25       Impact factor: 2.502

8.  Accuracy of the Dinamap 1846 XT automated blood pressure monitor.

Authors:  E R Beaubien; C M Card; S E Card; H J Biem; T W Wilson
Journal:  J Hum Hypertens       Date:  2002-09       Impact factor: 3.012

  8 in total
  2 in total

1.  Patient-Specific Oscillometric Blood Pressure Measurement.

Authors:  Jiankun Liu; Hao-Min Cheng; Chen-Huan Chen; Shih-Hsien Sung; Mohsen Moslehpour; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  IEEE Trans Biomed Eng       Date:  2015-10-15       Impact factor: 4.538

2.  Validation of Central and Peripheral Non-Invasive Hemodynamic Variables Using an Oscillometric Method.

Authors:  Darío Echeverri; Alejandro Pizano; Jaime Cabrales; Karen Moreno
Journal:  High Blood Press Cardiovasc Prev       Date:  2017-10-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.