LASIK correction of spherical hyperopia, hyperopic astigmatism, and mixed astigmatism with the LADARVision excimer laser system.

James J Salz1, Christy A Stevens.   

Abstract

OBJECTIVE: To assess the safety and effectiveness of the LADARVision active tracking narrow beam excimer laser system (Alcon Surgical, Orlando, FL) using laser in situ keratomileusis (LASIK) for correction of spherical hyperopia, hyperopic astigmatism, and mixed astigmatism.
DESIGN: A multicenter, prospective non-randomized (self-controlled) comparative trial. PARTICIPANTS: A total of 360 eyes, including 152 spherical hyperopic, 143 hyperopic astigmatic, and 65 mixed astigmatic, were treated for up to +6.00-diopter (D) sphere with up to -6.00-D cylinder. INTERVENTION: Treatments were performed at six sites in the United States using a 6-mm optic zone with a 1.5-mm peripheral blend zone for a maximum ablation zone diameter of 9 mm. MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA), manifest refraction, vector analysis, best spectacle-corrected visual acuity (BSCVA), complications and adverse reactions, subjective symptoms, and patient satisfaction.
RESULTS: Six and 12 months of follow-up, respectively, were available on 143 and 117 spherical hyperopic eyes, 124 and 74 hyperopic astigmatic eyes, and 57 and 38 mixed astigmatic eyes, respectively. For spherical hyperopes at 6 and 12 months, UCVA was 20/40 or better in 93.4% and 93.9% of eyes, respectively. The manifest refraction spherical equivalent (MRSE) was within 0.50 D of intended in 65.0% and 74.1% of eyes, respectively, and within 1.00 D in 87.4% and 91.4%, respectively. Refractive stability was demonstrated in 94.2% or more of eyes between the intervals of 1 to 3 months and 3 to 6 months and in 95.3% or more of eyes to 12 months. A loss of two lines of BSCVA occurred in 3.5% and 3.4%, respectively, and no eyes lost more than two lines. For hyperopic astigmats at 6 and 12 months, UCVA was 20/40 or better in 90.9% and 93.8% of eyes, respectively. The MRSE was within 0.50 D of intended in 60.5% and 73.0% of eyes, respectively, and within 1.00 D in 88.7% and 89.2% of eyes, respectively. Refractive stability was demonstrated in 96.5% or more of eyes, respectively, between the intervals of 1 to 3 months and 3 to 6 months and 95.5% or more to 12 months. A loss of two lines of BSCVA occurred in 5.8% and 1.4% of eyes, respectively, and no eyes lost more than two lines. For mixed astigmats at 6 and 12 months, UCVA was 20/40 or better in 92.6% and 94.4% of eyes, respectively. The MRSE was within 0.50 D of intended in 64.9% and 73.7% of eyes, respectively, and within 1.00 D in 87.7% and 94.7% of eyes, respectively. Refractive stability was demonstrated in 100% of eyes between the intervals of 1 to 3 months and 3 to 6 months and in 97.0% or more to 12 months. A loss of two lines of BSCVA occurred in 1.9% and 0.0% of eyes, respectively, and no eyes lost more than two lines.
CONCLUSIONS: The data support safety and effectiveness of the LASIK correction of spherical hyperopia, hyperopic astigmatism, and mixed astigmatism with the LADARVision system.

Entities:  

Mesh:

Year:  2002        PMID: 12208711     DOI: 10.1016/s0161-6420(02)01133-8

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Conductive keratoplasty: a radiofrequency-based technique for the correction of hyperopia.

Authors:  Marguerite B McDonald
Journal:  Trans Am Ophthalmol Soc       Date:  2005

Review 2.  Errors in Treatment of Lower-order Aberrations and Induction of Higher-order Aberrations in Laser Refractive Surgery.

Authors:  Brad E Kligman; Brandon J Baartman; William J Dupps
Journal:  Int Ophthalmol Clin       Date:  2016

3.  Comparison of Wavelight Allegretto Eye-Q and Schwind Amaris 750S excimer laser in treatment of high astigmatism.

Authors:  Maja Bohac; Alma Biscevic; Mateja Koncarevic; Marija Anticic; Nikica Gabric; Sudi Patel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-08-23       Impact factor: 3.117

4.  Assessment of refractive outcome of femtosecond-assisted LASIK for hyperopia correction.

Authors:  Mohamed Tarek El-Naggar; Dikran Gilbert Hovaghimian
Journal:  Electron Physician       Date:  2017-03-25

5.  Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for hyperopia and hyperopic astigmatism refractive surgery.

Authors:  Bogdana Tăbăcaru; Horia Tudor Stanca; Ruxandra Angela Pîrvulescu; Simona Stanca; Ciprian Danielescu; Mihnea Munteanu; Cosmin Roșca; Adrian Cosmin Teodoru
Journal:  Exp Ther Med       Date:  2021-01-26       Impact factor: 2.447

6.  Refractive Outcomes After LASIK for the Treatment of Mixed Astigmatism with the Allegretto WaveLight EX500.

Authors:  Majid Moshirfar; Kathryn Durnford; Alin Megerdichian; Andrew Thomson; Tanisha Martheswaran; William West; Shannon McCabe; Yasmyne Ronquillo; Philip Hoopes
Journal:  Ophthalmol Ther       Date:  2022-02-15

7.  Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platform.

Authors:  Anastasios John Kanellopoulos
Journal:  Clin Ophthalmol       Date:  2012-06-12