Literature DB >> 12206631

Reconstruction of ultrasonic fields by deconvolving the hydrophone aperture effects. II. Experiment.

T Boutkedjirt1, R Reibold.   

Abstract

The correction of the averaging effect of finite-size hydrophones is at present realized by various methods which are based on idealized models for the sound field and thus are valid only to a limited extent. In the present article three methods for inverting the aperture effects of the hydrophone viz. the Wiener method, the power spectral equalization (PSE) method and the maximum a posteriori (MAP) method, are experimentally tested and their efficiency is compared. It is shown that both for a rectangular and for a circular hydrophone aperture all three methods are suitable to reconstruct complex sound field structures from spatially averaged data. The results of this paper confirm the finding of Part I [Ultrasonics 39 (2002) 603], i.e. the quality of reconstruction depends on the spatial frequency bandwidth of the sound field investigated. Good quality reconstructions are obtained when the effective dimensions of the hydrophone's sensing area are directly derived from the spatial frequency spectrum of the measurement signal. The Wiener method and the MAP method are superior to the PSE method, since the PSE filter does not take phase information into account. For the Wiener and the MAP method normalized correlation coefficients, r(pp), between the reconstructed sound pressure field and that of a reference measurement of typically 0.97 are obtained provided that the axial distance is not too small. Although the working frequency used for the experiments is rather low, it can be expected that the results obtained are applicable at higher frequencies provided that the complex spatial transfer function is determined with the necessary high precision.

Year:  2002        PMID: 12206631     DOI: 10.1016/s0041-624x(02)00347-5

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  6 in total

1.  Ultrasound field measurement using a binary lens.

Authors:  Gregory Clement; Hideyuki Nomura; Tomoo Kamakura
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model.

Authors:  Keith A Wear; Yunbo Liu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

4.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

5.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

6.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part I: Theory, Spatial-Averaging Correction Formulas, and Criteria for Sensitive Element Size.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.