Literature DB >> 12198965

Theoretical study of incomplete sampling of the first dimension in comprehensive two-dimensional chromatography.

John V Seeley1.   

Abstract

The process of regularly transferring material from the primary column to the secondary column is critical in producing comprehensive two-dimensional separations. A series of calculations have been performed to determine how sampling period, duty cycle, and sampling phase affect (1) the fraction of material transferred from the primary column to the secondary column, (2) the accuracy of primary retention time determination, and (3) the effective peak width along the primary retention axis. The results demonstrate that comprehensive two-dimensional separations can be produced without a substantial loss in quantitative precision and with only a moderate loss in primary column resolution if the sampling period is less than 1.5 times the primary peak standard deviation. The quantitative precision of total peak areas (for duty cycles less than 1.0) and primary retention time determination are rapidly reduced as the sampling period is increased above 1.5 times the primary peak standard deviation.

Mesh:

Year:  2002        PMID: 12198965     DOI: 10.1016/s0021-9673(02)00461-2

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  11 in total

Review 1.  Fast, comprehensive two-dimensional liquid chromatography.

Authors:  Dwight R Stoll; Xiaoping Li; Xiaoli Wang; Peter W Carr; Sarah E G Porter; Sarah C Rutan
Journal:  J Chromatogr A       Date:  2007-08-30       Impact factor: 4.759

2.  Improving peak capacity in fast online comprehensive two-dimensional liquid chromatography with post-first-dimension flow splitting.

Authors:  Marcelo R Filgueira; Yuan Huang; Klaus Witt; Cecilia Castells; Peter W Carr
Journal:  Anal Chem       Date:  2011-11-23       Impact factor: 6.986

3.  The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography.

Authors:  Lawrence W Potts; Dwight R Stoll; Xiaoping Li; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-07-15       Impact factor: 4.759

4.  An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography.

Authors:  Yuan Huang; Haiwei Gu; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-04-12       Impact factor: 4.759

5.  Effects of first dimension eluent composition in two-dimensional liquid chromatography.

Authors:  Xiaoping Li; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-02-16       Impact factor: 4.759

6.  Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.

Authors:  Robert C Allen; Sarah C Rutan
Journal:  Anal Chim Acta       Date:  2011-06-23       Impact factor: 6.558

7.  A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time.

Authors:  Dennis F Thekkudan; Sarah C Rutan; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-04-21       Impact factor: 4.759

8.  Equation for peak capacity estimation in two-dimensional liquid chromatography.

Authors:  Xiaoping Li; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2009-01-15       Impact factor: 6.986

9.  Dependence of effective peak capacity in comprehensive two-dimensional separations on the distribution of peak capacity between the two dimensions.

Authors:  Joe M Davis; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2008-10-08       Impact factor: 6.986

10.  Microchamber integration unifies distinct separation modes for two-dimensional electrophoresis.

Authors:  Augusto M Tentori; Alex J Hughes; Amy E Herr
Journal:  Anal Chem       Date:  2013-04-24       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.