Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy.

Christoph U Herborn1, Borut Marincek, Daniel Erfmann, Claudia Meuli-Simmen, Volker Wedler, Beate Bode-Lesniewska, Rahel A Kubik-Huch.   

Abstract

The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12195470     DOI: 10.1007/s00330-002-1362-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  11 in total

1.  Role of US in evaluating breast implant integrity.

Authors:  Michele Telegrafo; Marco Moschetta
Journal:  J Ultrasound       Date:  2015-06-23

Review 2.  Perspectives for preventive screening with total body MRI.

Authors:  Susanne C Ladd; Mark E Ladd
Journal:  Eur Radiol       Date:  2007-06-05       Impact factor: 5.315

3.  Indications for breast magnetic resonance imaging. Consensus document "Attualità in senologia", Florence 2007.

Authors:  F Sardanelli; G M Giuseppetti; G Canavese; L Cataliotti; S Corcione; E Cossu; M Federico; L Marotti; L Martincich; P Panizza; F Podo; M Rosselli Del Turco; C Zuiani; C Alfano; M Bazzocchi; P Belli; S Bianchi; A Cilotti; M Calabrese; L Carbonaro; L Cortesi; C Di Maggio; A Del Maschio; A Esseridou; A Fausto; M Gennaro; R Girometti; R Ienzi; A Luini; S Manoukian; S Morassutt; D Morrone; J Nori; A Orlacchio; F Pane; P Panzarola; R Ponzone; G Simonetti; P Torricelli; G Valeri
Journal:  Radiol Med       Date:  2008-10-16       Impact factor: 3.469

Review 4.  The effect of study design biases on the diagnostic accuracy of magnetic resonance imaging for detecting silicone breast implant ruptures: a meta-analysis.

Authors:  Jae W Song; Hyungjin Myra Kim; Lillian T Bellfi; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2011-03       Impact factor: 4.730

5.  Rare breast neoplasms: is there any peculiar feature on magnetic resonance mammography?

Authors:  A Linda; V Londero; F Mazzarella; C Zuiani; M Bazzocchi
Journal:  Radiol Med       Date:  2007-09-20       Impact factor: 3.469

6.  Imaging of breast implants-a pictorial review.

Authors:  Sergi Juanpere; Elsa Perez; Oscar Huc; Naiara Motos; Josep Pont; Salvador Pedraza
Journal:  Insights Imaging       Date:  2011-08-07

Review 7.  Magnetic resonance imaging of breast augmentation: a pictorial review.

Authors:  Ting Wong; Lai Wan Lo; Po Yan Eliza Fung; Hiu Yan Miranda Lai; Hoi Lam Helen She; Wing Kei Carol Ng; King Ming Kimmy Kwok; Chiu Man Lee
Journal:  Insights Imaging       Date:  2016-03-09

Review 8.  Tissue expansion for breast reconstruction: Methods and techniques.

Authors:  Nicolò Bertozzi; Marianna Pesce; PierLuigi Santi; Edoardo Raposio
Journal:  Ann Med Surg (Lond)       Date:  2017-07-21

9.  Removing silicone artifacts in diffusion-weighted breast MRI by means of shift-resolved spatiotemporally encoding.

Authors:  Eddy Solomon; Noam Nissan; Rita Schmidt; Edna Furman-Haran; Uriel Ben-Aharon; Lucio Frydman
Journal:  Magn Reson Med       Date:  2015-06-22       Impact factor: 4.668

10.  Long-term safety and effectiveness of style 410 highly cohesive silicone breast implants.

Authors:  Per Hedén; Giorgio Bronz; Jens Jorgen Elberg; Rika Deraemaecker; Diane K Murphy; Araceli Slicton; R James Brenner; Catarina Svarvar; Joost van Tetering; Leo Peter van der Weij
Journal:  Aesthetic Plast Surg       Date:  2009-05-13       Impact factor: 2.326

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.