Literature DB >> 12163623

Quantitative evaluation of myocardial blood flow and ejection fraction with a single dose of (13)NH(3) and Gated PET.

Hidehiko Okazawa1, Masaaki Takahashi, Tatsuhiko Hata, Kanji Sugimoto, Yoshihiko Kishibe, Takafumi Tsuji.   

Abstract

UNLABELLED: To evaluate myocardial blood flow (MBF) and cardiac function with a single dose of (13)NH(3), electrocardiographically (ECG) gated PET acquisition was performed after a dynamic PET scan was obtained. Gated blood-pool (GBP) imaging with C(15)O PET was also performed to compare the left ventricular ejection fraction (LVEF) obtained using the 2 methods.
METHODS: Six healthy volunteers and 34 patients with cardiovascular disease were studied. Each subject underwent dynamic PET scanning after a slow intravenous injection of approximately 740 MBq (13)NH(3), followed by ECG gated PET scanning. MBF images were calculated by the Patlak plot method. Before obtaining the (13)NH(3) scan, the GBP image was obtained with a bolus inhalation of C(15)O. Twenty patients also underwent left ventriculography (LVG) to compare the value of the LVEF obtained using this technique with that determined using the gated PET method.
RESULTS: The mean regional value of MBF calculated for healthy volunteers in the resting condition was 0.61 +/- 0.10 mL/min/g. The LVEF obtained using GBP PET (EF(CO)) was consistent with that obtained using LVG. The LVEF calculated from gated (13)NH(3) scans (EF(NH3)) correlated well with EF(CO), although EF(NH3) slightly underestimated the LVEF (EF(NH3) = 0.97. EF(CO) - 2.94; r = 0.87). EF(NH3) was significantly different from EF(CO) in patients with a perfusion defect in the cardiac wall (EF(NH3) = 39% +/- 11% vs. EF(CO) = 45% +/- 11%; n = 19; P < 0.001), whereas no significant difference was found between them in subjects with no defect (EF(NH3) = 58% +/- 13% vs. EF(CO) = 61% +/- 10%; n = 21).
CONCLUSION: Gated PET acquisition accompanied by obtaining a dynamic PET scan with a single dose of (13)NH(3) is a promising method for the simultaneous clinical evaluation of MBF and cardiac function. However, in patients with a defect in the cardiac wall, EF(NH3) showed a tendency to underestimate the EF compared with EF(CO).

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12163623

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  11 in total

1.  Measurement of left ventricular volumes and function using O-15-labeled carbon monoxide gated PET.

Authors:  Philipp A Kaufmann
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

2.  Acute hyperglycemia causes microvascular damage, leading to poor functional recovery and remodeling in patients with reperfused ST-segment elevation myocardial infarction.

Authors:  Katsuhiko Sarazawa; Akira Nakano; Hiroyasu Uzui; Yasuhiko Mitsuke; Tohru Geshi; Hidehiko Okazawa; Takanori Ueda; Jong-Dae Lee
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

3.  Measurement of left ventricular volumes and function with O-15-labeled carbon monoxide gated positron emission tomography: comparison with magnetic resonance imaging.

Authors:  Hadassa A Hofman; Paul Knaapen; Ronald Boellaard; Olga Bondarenko; Marco J W Götte; Willem G van Dockum; Cees A Visser; Albert C van Rossum; Adriaan A Lammertsma; Frans C Visser
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

4.  Impaired myocardial microcirculation in the flow-glucose metabolism mismatch regions in revascularized acute myocardial infarction.

Authors:  Yoshitomo Fukuoka; Akira Nakano; Naoto Tama; Kanae Hasegawa; Hiroyuki Ikeda; Tetsuji Morishita; Kentaro Ishida; Kenichi Kaseno; Naoki Amaya; Hiroyasu Uzui; Hidehiko Okazawa; Hiroshi Tada
Journal:  J Nucl Cardiol       Date:  2016-06-14       Impact factor: 5.952

5.  Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET: a comparison with cardiac magnetic resonance imaging.

Authors:  Wolfgang M Schaefer; Claudia S A Lipke; Bernd Nowak; Hans Juergen Kaiser; Arno Buecker; Gabriele A Krombach; Udalrich Buell; Harald P Kühl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-02-15       Impact factor: 9.236

6.  The reproducibility of time-of-flight PET and conventional PET for the quantification of myocardial blood flow and coronary flow reserve with (13)N-ammonia.

Authors:  Masaya Suda; Masahisa Onoguchi; Takeshi Tomiyama; Keiichi Ishihara; Naoto Takahashi; Minoru Sakurai; Keiichi Matsumoto; Shin-Ichiro Kumita
Journal:  J Nucl Cardiol       Date:  2015-03-17       Impact factor: 5.952

7.  Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging.

Authors:  Nina Burkhard; Bernhard A Herzog; Lars Husmann; Aju P Pazhenkottil; Irene A Burger; Ronny R Buechel; Ines Valenta; Christophe A Wyss; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-23       Impact factor: 9.236

8.  Comparison of gated N-13 ammonia PET and gated Tc-99m sestamibi SPECT for quantitative analysis of global and regional left ventricular function.

Authors:  Sugako Kanayama; Ichiro Matsunari; Koji Kajinami
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

9.  First-pass cardiac PET: Potentiality and limitations.

Authors:  Luca Camoni; Elisabetta Cerudelli
Journal:  J Nucl Cardiol       Date:  2021-02-18       Impact factor: 3.872

10.  Stroke volume measurements with first-pass dynamic positron emission tomography: comparison with cardiovascular magnetic resonance.

Authors:  Paul Knaapen; Mark Lubberink; Luuk J Rijzewijk; Rutger W van der Meer; Michiel Unger; Tjeerd Germans; Jeroen J Bax; Jan W A Smit; Hildo J Lamb; Albert C van Rossum; Michaela Diamant; Frans C Visser; Adriaan A Lammertsma
Journal:  J Nucl Cardiol       Date:  2008 Mar-Apr       Impact factor: 3.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.