Literature DB >> 12160702

Electron tomographic analysis of frozen-hydrated tissue sections.

Chyong-Ere Hsieh1, Michael Marko, Joachim Frank, Carmen A Mannella.   

Abstract

Electron tomography of frozen-hydrated tissue sections enables analysis of the 3-D structure of cell organelles in situ and in a near-native state. In this study, 160-200-nm-thick sections were cut from high-pressure frozen rat liver, and improved methods were used for handling and mounting the sections. Automated data collection facilitated tilt-series recording at low electron dose (approximately 4000 e(-)/nm(2) at 400 keV). Higher doses (up to 10,000 e(-)/nm(2)) were found to increase contrast and smooth out surface defects, but caused section distortion and movement, with likely loss of high-resolution information. Tomographic reconstruction showed that knife marks were 10-40 nm deep and located on the "knife face" of the section, while crevices were 20-50 nm deep and found on the "block face." The interior of the section was normally free of defects, except for compression, and contained useful structural information. For example, the topology of mitochondrial membranes in tissue was found to be very similar to that in frozen-hydrated whole mounts of isolated mitochondria. In rare cases, a 15-nm banding pattern perpendicular to the cutting direction was observed in the interior of the section, most evident in the uniformly dense, protein-rich material of the mitochondrial matrix.

Entities:  

Mesh:

Year:  2002        PMID: 12160702     DOI: 10.1016/s1047-8477(02)00034-5

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  22 in total

1.  Electron tomography of frozen-hydrated isolated triad junctions.

Authors:  T Wagenknecht; C-E Hsieh; B K Rath; S Fleischer; M Marko
Journal:  Biophys J       Date:  2002-11       Impact factor: 4.033

2.  Cryo-transmission electron microscopy of frozen-hydrated sections of Escherichia coli and Pseudomonas aeruginosa.

Authors:  Valério R F Matias; Ashraf Al-Amoudi; Jacques Dubochet; Terry J Beveridge
Journal:  J Bacteriol       Date:  2003-10       Impact factor: 3.490

3.  Methods for generating high-resolution structural models from electron microscope tomography data.

Authors:  David B Ress; Mark L Harlow; Robert M Marshall; Uel J McMahan
Journal:  Structure       Date:  2004-10       Impact factor: 5.006

4.  The mammalian central nervous synaptic cleft contains a high density of periodically organized complexes.

Authors:  Benoît Zuber; Irina Nikonenko; Paul Klauser; Dominique Muller; Jacques Dubochet
Journal:  Proc Natl Acad Sci U S A       Date:  2005-12-14       Impact factor: 11.205

5.  Cryo-electron tomography reveals the comparative three-dimensional architecture of Prochlorococcus, a globally important marine cyanobacterium.

Authors:  Claire S Ting; Chyongere Hsieh; Sesh Sundararaman; Carmen Mannella; Michael Marko
Journal:  J Bacteriol       Date:  2007-04-20       Impact factor: 3.490

Review 6.  3D electron microscopy of biological nanomachines: principles and applications.

Authors:  C O S Sorzano; S Jonic; M Cottevieille; E Larquet; N Boisset; S Marco
Journal:  Eur Biophys J       Date:  2007-07-05       Impact factor: 1.733

7.  Determination of quantitative distributions of heavy-metal stain in biological specimens by annular dark-field STEM.

Authors:  A A Sousa; M Hohmann-Marriott; M A Aronova; G Zhang; R D Leapman
Journal:  J Struct Biol       Date:  2008-01-26       Impact factor: 2.867

8.  On the feasibility of visualizing ultrasmall gold labels in biological specimens by STEM tomography.

Authors:  A A Sousa; M A Aronova; Y C Kim; L M Dorward; G Zhang; R D Leapman
Journal:  J Struct Biol       Date:  2007-06-28       Impact factor: 2.867

Review 9.  Advances in tomography: probing the molecular architecture of cells.

Authors:  Karen Fridman; Asaf Mader; Monika Zwerger; Natalie Elia; Ohad Medalia
Journal:  Nat Rev Mol Cell Biol       Date:  2012-10-10       Impact factor: 94.444

10.  Thinning of large mammalian cells for cryo-TEM characterization by cryo-FIB milling.

Authors:  K M Strunk; K Wang; D Ke; J L Gray; P Zhang
Journal:  J Microsc       Date:  2012-09       Impact factor: 1.758

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.