Literature DB >> 12145134

CT-MRI image fusion for delineation of volumes in three-dimensional conformal radiation therapy in the treatment of localized prostate cancer.

G L Sannazzari1, R Ragona, M G Ruo Redda, F R Giglioli, G Isolato, A Guarneri.   

Abstract

The objective of this study was to assess the utility of CT-MRI image fusion software and compare both prostate volume and localization with CT and MRI studies. We evaluated the differences in clinical volumes in patients undergoing three-dimensional conformal radiation therapy for localized prostate cancer. After several tests performed to ensure the quality of image fusion software, eight patients suffering from prostate adenocarcinoma were submitted to CT and MRI studies in the treatment position within an immobilization device before the start of radiotherapy. The clinical target volume (CTV) (prostate plus seminal vesicles) was delineated on CT and MRI studies and image fusion was obtained from the superimposition of anatomical fiducial markers. A comparison of dose-volume histograms relative to CTV, rectum, bladder and femoral heads was performed for both studies. Image fusion showed a mean overestimation of CTV of 34% with CT compared with MRI. Along the anterior-posterior and superior-inferior direction, CTV was a mean 5 mm larger with CT study compared with MRI. The dose-volume histograms resulting from CT and MRI comparison showed that it is possible to spare a mean 10% of rectal volume and approximately 5% of bladder and femoral heads, respectively. This study confirmed an overestimation of CTV with CT images compared with MRI. Because this finding only allows a minimal sparing of organs at risk, considering the organ motion during each radiotherapy session and the excellent outcomes of prostate cancer treatment with CT based target identification, we are still reluctant to reduce the CTV to that identified by MRI.

Entities:  

Mesh:

Year:  2002        PMID: 12145134     DOI: 10.1259/bjr.75.895.750603

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  24 in total

1.  Concurrent segmentation of the prostate on MRI and CT via linked statistical shape models for radiotherapy planning.

Authors:  Najeeb Chowdhury; Robert Toth; Jonathan Chappelow; Sung Kim; Sabin Motwani; Salman Punekar; Haibo Lin; Stefan Both; Neha Vapiwala; Stephen Hahn; Anant Madabhushi
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Definition of the CTV prostate in CT and MRI by using CT-MRI image fusion in IMRT planning for prostate cancer.

Authors:  Bettina Hentschel; Wolfgang Oehler; Dirk Strauss; Andreas Ulrich; Ansgar Malich
Journal:  Strahlenther Onkol       Date:  2011-02-24       Impact factor: 3.621

3.  The influence of MRI scan position on image registration accuracy, target delineation and calculated dose in prostatic radiotherapy.

Authors:  S Hanvey; A H Sadozye; M McJury; M Glegg; J Foster
Journal:  Br J Radiol       Date:  2012-12       Impact factor: 3.039

4.  Dual-core steered non-rigid registration for multi-modal images via bi-directional image synthesis.

Authors:  Xiaohuan Cao; Jianhua Yang; Yaozong Gao; Yanrong Guo; Guorong Wu; Dinggang Shen
Journal:  Med Image Anal       Date:  2017-05-13       Impact factor: 8.545

5.  Multimodal image registration for the identification of dominant intraprostatic lesion in high-precision radiotherapy treatments.

Authors:  Delia Ciardo; Barbara Alicja Jereczek-Fossa; Giuseppe Petralia; Giorgia Timon; Dario Zerini; Raffaella Cambria; Elena Rondi; Federica Cattani; Alessia Bazani; Rosalinda Ricotti; Maria Garioni; Davide Maestri; Giulia Marvaso; Paola Romanelli; Marco Riboldi; Guido Baroni; Roberto Orecchia
Journal:  Br J Radiol       Date:  2017-08-22       Impact factor: 3.039

6.  Simultaneous integrated boost to intraprostatic lesions using different energy levels of intensity-modulated radiotherapy and volumetric-arc therapy.

Authors:  C Onal; S Sonmez; G Erbay; O C Guler; G Arslan
Journal:  Br J Radiol       Date:  2013-12-06       Impact factor: 3.039

7.  Enhancing the utility of prostascint SPECT scans for patient management.

Authors:  Marilyn E Noz; Grace Chung; Benjamin Y Lee; Gerald Q Maguire; J Keith DeWyngaert; Jay V Doshi; Elissa L Kramer; Antoinette D Murphy-Walcott; Michael P Zeleznik; Noeun G Kwak
Journal:  J Med Syst       Date:  2006-04       Impact factor: 4.460

8.  Converting from CT- to MRI-only-based target definition in radiotherapy of localized prostate cancer: A comparison between two modalities.

Authors:  Tiina Seppälä; Harri Visapää; Juhani Collan; Mika Kapanen; Annette Beule; Mauri Kouri; Mikko Tenhunen; Kauko Saarilahti
Journal:  Strahlenther Onkol       Date:  2015-07-14       Impact factor: 3.621

Review 9.  Advances in MR spectroscopy of the prostate.

Authors:  John Kurhanewicz; Daniel B Vigneron
Journal:  Magn Reson Imaging Clin N Am       Date:  2008-11       Impact factor: 2.266

10.  Sparse patch-based label propagation for accurate prostate localization in CT images.

Authors:  Shu Liao; Yaozong Gao; Jun Lian; Dinggang Shen
Journal:  IEEE Trans Med Imaging       Date:  2012-11-27       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.