Radiation dose quantities and risk in neonates in a special care baby unit.

C I Armpilia1, I A J Fife, P L Croasdale.   

Abstract

Radiographs are taken in the neonatal period most commonly to assist in the diagnosis and management of respiratory difficulties. Frequent accurate radiographic assessment is required and a knowledge of the radiation dose is necessary to justify such exposures. A survey of radiation doses to neonates from diagnostic radiography (chest and abdomen) has been carried out in the special care baby unit of the Royal Free Hospital. Entrance surface dose (ESD) was calculated from quality control measurements on the X-ray unit itself. Direct measurement of radiation doses was also performed using highly sensitive thermoluminescent dosemeters (TLDs) (LiF:Mg,Cu,P), calibrated and tested for consistency in sensitivity. ESD, as calculated from exposure parameters, was found to range from 28 microGy to 58 microGy, with a mean ESD per radiograph of 36+/-6 microGy averaged over 95 examinations. ESDs as derived from TLD crystals ranged from 18 microGy to 58 microGy for 30 radiographic examinations. The mean energy imparted, the mean whole body dose per radiograph and the mean effective dose were estimated to be 14+/-8 microJ, 10+/-4 microGy and 8+/-2 microSv, respectively. Assuming that neonates and fetuses are equally susceptible to carcinogenic effects of radiation, which involve an overestimation of risk, the radiation risk of childhood cancer from a single radiograph was estimated to be of the order (0.3-1.3) x 10(-6). Radiation doses compared favourably with the reference values of 80 microGy ESD published by the Commission of the European Communities in 1996, and 50 microGy published by the National Radiological Protection Board in 2000.

Entities:  

Mesh:

Year:  2002        PMID: 12145132     DOI: 10.1259/bjr.75.895.750590

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  13 in total

1.  Image quality and dose differences caused by vendor-specific image processing of neonatal radiographs.

Authors:  William F Sensakovic; M Cody O'Dell; Haley Letter; Nathan Kohler; Baiywo Rop; Jane Cook; Gregory Logsdon; Laura Varich
Journal:  Pediatr Radiol       Date:  2016-08-03

2.  Visual grading analysis of digital neonatal chest phantom X-ray images: Impact of detector type, dose and image processing on image quality.

Authors:  M H Smet; L Breysem; E Mussen; H Bosmans; N W Marshall; L Cockmartin
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

3.  Quantification of scatter radiation from radiographic procedures in a neonatal intensive care unit.

Authors:  Mariaconcetta Longo; Elisabetta Genovese; Salvatore Donatiello; Bartolomeo Cassano; Teresa Insero; Mauro Campoleoni; Antonella Del Vecchio; Andrea Magistrelli; Paolo Tomà; Vittorio Cannatà
Journal:  Pediatr Radiol       Date:  2018-02-13

4.  Chest radiographs after removal of chest drains in neonates: clinical benefit or common practice?

Authors:  J van den Boom; M Battin
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-06-12       Impact factor: 5.747

Review 5.  [Digital radiography of the chest in pediatric patients].

Authors:  S Puig
Journal:  Radiologe       Date:  2003-12       Impact factor: 0.635

6.  Pulmonary ultrasonography in the follow-up of respiratory distress syndrome on preterm newborns. Reduction of X-ray exposure.

Authors:  M Federici; P V Federici; F Feleppa; C Gizzi; R Agostino; A Bellelli; V David
Journal:  J Ultrasound       Date:  2011-05-06

7.  Radiation exposure to premature infants in a neonatal intensive care unit in Turkey.

Authors:  Turan Olgar; Esra Onal; Dogan Bor; Nurullah Okumus; Yildiz Atalay; Canan Turkyilmaz; Ebru Ergenekon; Esin Koc
Journal:  Korean J Radiol       Date:  2008 Sep-Oct       Impact factor: 3.500

8.  Organ doses in preterm and full-term neonates and infants - a retrospective study on 1,064 chest radiographs.

Authors:  Birgit Kammer; Karl O Schneider; Evi Dell'Agnolo; Michael C Seidenbusch
Journal:  Pediatr Radiol       Date:  2022-03-18

9.  Radiation dose to newborns in neonatal intensive care units.

Authors:  Mohammad Taghi Bahreyni Toossi; Malakeh Malekzadeh
Journal:  Iran J Radiol       Date:  2012-09-17       Impact factor: 0.212

10.  Assessment of chest X-ray images in newborns with respiratory disorders.

Authors:  Łukasz Maciej Czarnecki
Journal:  Kardiochir Torakochirurgia Pol       Date:  2015-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.