Literature DB >> 12144233

Management of pellucid marginal corneal degeneration with rigid gas permeable contact lenses.

Viswanadh B Kompella1, Murali K Aasuri, Gullapalli N Rao.   

Abstract

PURPOSE: To study the clinical performance of rigid gas permeable contact lenses (RGPCL) in patients with pellucid marginal corneal degeneration (PMCD).
METHODS: This retrospective study consisted of 15 patients with clinical PMCD, confirmed by videokeratography (TMS-1, Computed Anatomy, Inc., New York, NY). Information collected from the medical records included patient demographic data, uncorrected visual acuity, refraction, best-corrected spectacle visual acuity, and topographic details, including kerotometry. Twenty-seven of 30 eyes were subjected to several contact lens trials using polymethylmethacrylate (PMMA) contact lenses, using a systematic and consistent approach. After successful contact lens trials, data regarding number of trials, trial time, final contact lens choice parameters, and best-corrected contact lens visual acuity were noted for each patient. During follow-up, visual acuity with RGPCLs, lens fit, and average wearing time were noted.
RESULTS: Fifteen patients (30 eyes) with typically inferiorly located pellucid marginal corneal degeneration were included in this study. There were 12 men and 3 women, with a mean age of 39.73 years. Twenty-seven eyes of 15 patients were identified as subjects for multiple contact lens trials, and 24 (88.8%) eyes were successfully fitted with RGPCLs. Best-corrected visual acuity of 6/12 or better with spectacles was achieved in 14 (46.66%) eyes. The average astigmatism was -8.56D, and a majority of the patients with PMCD who were in the contact lens trial had an against-the-rule astigmatism (63.3%). The mean trial time for attempted eyes (i.e., patients with PMCD who successfully underwent the contact lens trials) was 77.7 minutes, and the number of trials required to finalize the choice of contact lenses ranged between 2 and 7. The median base curve for RGP lenses was 7.57, and median diameter was 10.00 mm. Best-corrected visual acuity of 6/12 or better with the final contact lens was achieved in 95.4% of the subjects. After an average follow-up of 22.91 months, one patient was lost to follow-up, and 2 eyes required discontinuation of the contact lenses. The average wearing time among the contact lens wearers at their last follow-up visits was 9.58 hours. Final visual acuity of 6/12 or better was observed in 77.3% of eyes at the end of 22.91 months.
CONCLUSION: Large-diameter RGPCLs are better tolerated and lead to significant improvement in visual acuity in inferior PMCD.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12144233

Source DB:  PubMed          Journal:  CLAO J        ISSN: 0733-8902


  10 in total

1.  Mini-incision cataract surgery and toric lens implantation for the reduction of high myopic astigmatism in patients with pellucid marginal degeneration.

Authors:  A Balestrazzi; S Baiocchi; A Balestrazzi; G Cartocci; G M Tosi; G Martone; P Michieletto
Journal:  Eye (Lond)       Date:  2015-02-27       Impact factor: 3.775

2.  National survey of pellucid marginal corneal degeneration in Japan.

Authors:  Jun Shimazaki; Naoyuki Maeda; Osamu Hieda; Yuichi Ohashi; Akira Murakami; Kohji Nishida; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2016-07-11       Impact factor: 2.447

3.  Outcome of complete intrastromal ring implantation using femtosecond laser in pellucid marginal degeneration.

Authors:  M Jabbarvand; H Hashemian; M Khodaparast; F Bazvand; A Beheshtnejad
Journal:  Eye (Lond)       Date:  2015-03-27       Impact factor: 3.775

4.  Pellucid marginal degeneration and bilateral corneal perforation: case report and review of the literature.

Authors:  William Barry Lee; Henry S O'Halloran; Hans E Grossniklaus
Journal:  Eye Contact Lens       Date:  2008-07       Impact factor: 2.018

5.  Pellucid marginal corneal degeneration: evaluation of the corneal surface and contact lens fitting.

Authors:  C Gruenauer-Kloevekorn; U Fischer; K Kloevekorn-Norgall; G I W Duncker
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

6.  Corneal Collagen Cross-Linking in Pellucid Marginal Degeneration: 2 Patients, 4 Eyes.

Authors:  Serife Bayraktar; Zafer Cebeci; Merih Oray; Nilufer Alparslan
Journal:  Case Rep Ophthalmol Med       Date:  2015-05-11

7.  Full-Ring Intracorneal Implantation in Corneas With Pellucid Marginal Degeneration.

Authors:  Sahar Mojaled Nobari; Consuelo Villena; Khosrow Jadidi
Journal:  Iran Red Crescent Med J       Date:  2015-12-26       Impact factor: 0.611

Review 8.  Nonsurgical Procedures for Keratoconus Management.

Authors:  L Rico-Del-Viejo; M Garcia-Montero; J L Hernández-Verdejo; S García-Lázaro; F J Gómez-Sanz; A Lorente-Velázquez
Journal:  J Ophthalmol       Date:  2017-12-21       Impact factor: 1.909

9.  Corneal Cross-Linking in Pellucid Marginal Degeneration: Evaluation after Five Years.

Authors:  Matin Irajpour; Pegah Noorshargh; Alireza Peyman
Journal:  J Curr Ophthalmol       Date:  2022-07-26

10.  Demographic, clinical and tomographic characteristics of pellucid marginal degeneration patients in South Egyptian population.

Authors:  Amr Mounir; Marwa Mahmoud Abdellah; Islam Awny; Ahmed Hassan Aldghaimy; Engy Mohamed Mostafa
Journal:  Int Ophthalmol       Date:  2022-08-24       Impact factor: 2.029

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.