Literature DB >> 25721517

Mini-incision cataract surgery and toric lens implantation for the reduction of high myopic astigmatism in patients with pellucid marginal degeneration.

A Balestrazzi2, S Baiocchi1, A Balestrazzi2, G Cartocci1, G M Tosi1, G Martone1, P Michieletto2.   

Abstract

PURPOSE: To evaluate the clinical outcomes, safety, and efficacy of cataract surgery with the implantation of a toric intraocular lens (IOL) in eyes with stable pellucid marginal degeneration (PMD).
METHODS: Eleven eyes (eight patients) diagnosed as stable PMD and cataract underwent mini-incision 2.2 mm cataract surgery followed by the implantation of hydrophobic toric aspheric IOL (AcrySof IQ Toric IOL, Alcon, Fort Worth, TX, USA). Perioperative variables of interest included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and corneal topography. Paired samples t-tests were used to analyze preoperative and postoperative visual acuity, astigmatism, and spherical equivalent (SE) parameters. Follow-up was 6 months.
RESULTS: The mean CDVA was 0.62±0.26 logMAR preoperatively and 0.07±0.07 logMAR postoperatively. The mean preoperative sphere and cylinder was -3.14±3.58D and -4.84±2.02D, respectively. The mean postoperative manifest refractive sphere and cylinder was -0.30±0.51D and -0.81±1.51D, respectively. There was a significant reduction in refractive astigmatism after toric IOL implantation (P<0.002). The toric IOL axis rotation was <5° in all cases at the final follow-up.
CONCLUSIONS: Implantation of hydrophobic toric IOL was a safe and effective surgical procedure to correct mild to moderate stable PMD.

Entities:  

Mesh:

Year:  2015        PMID: 25721517      PMCID: PMC4429272          DOI: 10.1038/eye.2015.13

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  19 in total

1.  Management of pellucid marginal corneal degeneration.

Authors:  Patrick F Tzelikis; Elisabeth J Cohen; Christopher J Rapuano; Kristin M Hammersmith; Peter R Laibson
Journal:  Cornea       Date:  2005-07       Impact factor: 2.651

2.  Pellucid marginal corneal degeneration.

Authors:  J H Krachmer
Journal:  Arch Ophthalmol       Date:  1978-07

Review 3.  Intracorneal ring segments in ectatic corneal disease - a review.

Authors:  David P Piñero; Jorge L Alio
Journal:  Clin Exp Ophthalmol       Date:  2010-03       Impact factor: 4.207

4.  Posterior chamber toric phakic intraocular lens implantation for high myopic astigmatism in eyes with pellucid marginal degeneration.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Fumika Hikita; Mari Komatsu
Journal:  J Cataract Refract Surg       Date:  2010-01       Impact factor: 3.351

5.  Customized ultra-high-power toric intraocular lens implantation for pellucid marginal degeneration and cataract.

Authors:  Jonathan Luck
Journal:  J Cataract Refract Surg       Date:  2010-07       Impact factor: 3.351

Review 6.  Status of toric intraocular lenses.

Authors:  Jeffrey D Horn
Journal:  Curr Opin Ophthalmol       Date:  2007-02       Impact factor: 3.761

7.  Corneal collagen cross-linking with riboflavin and UVA irradiation in pellucid marginal degeneration.

Authors:  Leopoldo Spadea
Journal:  J Refract Surg       Date:  2010-05       Impact factor: 3.573

8.  Repeatability of refraction and corrected visual acuity in keratoconus. The CLEK Study Group. Collaborative Longitudinal Evaluation of Keratoconus.

Authors:  L J Davis; K B Schechtman; C G Begley; J A Shin; K Zadnik
Journal:  Optom Vis Sci       Date:  1998-12       Impact factor: 1.973

9.  Use of Verisyse/Artisan phakic intraocular lens for the reduction of myopia in a patient with pellucid marginal degeneration.

Authors:  Niels E de Vries; Nayyirih G Tahzib; Carroll A B Webers; Fred Hendrikse; Rudy M M A Nuijts
Journal:  Cornea       Date:  2008-02       Impact factor: 2.651

10.  [Cataract surgery with implantation of toric silicone lenses for severe astigmatism after keratoplasty].

Authors:  H-J Buchwald; G K Lang
Journal:  Klin Monbl Augenheilkd       Date:  2004-06       Impact factor: 0.700

View more
  3 in total

Review 1.  Intraocular lens power calculation in keratoconus; A review of literature.

Authors:  Leila Ghiasian; Navid Abolfathzadeh; Navid Manafi; Ali Hadavandkhani
Journal:  J Curr Ophthalmol       Date:  2019-03-15

2.  An innovative approach for determining the customized refractive index of ectatic corneas in cataractous patients.

Authors:  Shiva Pirhadi; Keivan Maghooli; Khosrow Jadidi
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

3.  Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration.

Authors:  Himanshu Matalia; Chinnappaiah Nandini; Jyoti Matalia
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.