Literature DB >> 12130403

A biomechanical analysis of meniscal repair techniques.

Christopher C Rankin1, David M Lintner, Philip C Noble, Vibor Paravic, Erin Greer.   

Abstract

BACKGROUND: Various methods are available for repair of meniscal tears: a biodegradable meniscal implant without sutures (Biofix meniscus arrow), a suture anchor device (T-fix), and horizontal and vertical mattress sutures. HYPOTHESIS: There is no difference in repair strength or mode of failure among the techniques compared. STUDY
DESIGN: Controlled laboratory study.
METHODS: Reproducible tears were created in bovine menisci and repaired with each of the techniques. Residual displacement of the tear immediately after repair and the resistance to displacement under load applied perpendicular to the tear were measured and compared.
RESULTS: The residual displacement after repair was highest in the Biofix arrow group (0.70 mm) and lowest in the vertical mattress suture group (0.21 mm). The ultimate strength of repair was strongest for the vertical sutures (202 +/- 7 N) and lowest for the arrow and T-fix (95.9 +/- 8 N and 99.4 +/- 8 N, respectively). The force required to generate 2 mm of tear displacement was greatest for the vertical sutures (143 N) and least for the arrow (43.6 N).
CONCLUSIONS: Suture techniques were stronger at all levels of testing. CLINICAL RELEVANCE: Knowledge of biomechanical characteristics aids the surgeon in choosing the appropriate technique for each situation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12130403     DOI: 10.1177/03635465020300040801

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  20 in total

1.  A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

Authors:  Thore Zantop; Anne Kathleen Eggers; Volker Musahl; Andre Weimann; Joachim Hassenpflug; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-12-19       Impact factor: 4.342

2.  Mechanical comparison of meniscal repair devices with mattress suture devices in vitro.

Authors:  Brian C Aros; Angela Pedroza; William K Vasileff; Alan S Litsky; David C Flanigan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-09       Impact factor: 4.342

3.  Meniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study.

Authors:  Yavuz Kocabey; Omer Taşer; Onur Hapa; Aycan Güçlü; Ergun Bozdag; Emin Sünbüloglu; Mahmutnedim Doral
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-03       Impact factor: 4.342

4.  Clinical Results of Meniscal Repair Using Submeniscal Horizontal Sutures.

Authors:  Amir Mohammad Navali; Hossein Aslani
Journal:  Arch Bone Jt Surg       Date:  2015-07

5.  Evaluation of the second-generation meniscus arrow in the fixation of bucket-handle tears in the vascular area of the meniscus. A prospective study of 20 patients with a mean follow-up of 26 months.

Authors:  Janne Sarimo; Jussi Rantanen; Tapio Tarvainen; Markku Härkönen; Sakari Orava
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-05-05       Impact factor: 4.342

6.  Pullout strength of meniscal repair after cyclic loading: comparison of vertical, horizontal, and oblique suture techniques.

Authors:  Yavuz Kocabey; Omer Taser; John Nyland; Mahmut Nedim Doral; Mehmet Demirhan; David N M Caborn; Sezgin Sarban
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-05-04       Impact factor: 4.342

7.  Mid-term clinical results of medial meniscus repair with the meniscus arrow in the unstable knee.

Authors:  Nikolaos Koukoulias; Stergios Papastergiou; Konstantinos Kazakos; Georgios Poulios; Konstantinos Parisis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-12       Impact factor: 4.342

8.  Biomechanical evaluation of arthroscopic all-inside meniscus repairs.

Authors:  Taner Gunes; Bora Bostan; Mehmet Erdem; Murat Asci; Cengiz Sen; Mehmet Halidun Kelestemur
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

9.  The effect of inclination angle on the strength of vertical mattress configuration for meniscus repair.

Authors:  Mehmet Erduran; Onur Hapa; Baran Şen; Yavuz Kocabey; Diler Erdemli; Mehran Aksel; Hasan Havitçioğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-09       Impact factor: 4.342

Review 10.  [Complications with all-inside devices used in reconstructive meniscal surgery].

Authors:  P Wilmes; O Lorbach; P Brogard; R Seil
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.