Errors in data derived from pulmonary artery blood gas values.

P M Suter, J M Lindauer, H B Fairley, R M Schlobohm.   

Abstract

Blood gas values were obtained from Swan-Ganz pulmonary artery catheters in 25 patients with acute pulmonary failure, with the objective of evaluating the possibility of contamination with "arterialized" blood and examining the mechanism by which this might happen. Blood oxygen content increased significantly from the main to a segmental pulmonary artery, proportional to the withdrawal rate of the sample. At 3 ml/min, distal contents ranged from 100 to 116% of proximal values (p less than 0.01). At 23 ml/min the range was 100-140% of proximal values (p less than 0.001). Sampling of blood from a Swan-Ganz catheter in the usual position for "wedge" pressure measurement, but with a balloon deflated, may lead to large errors in calculation of cardiac output by the Fick method and in calculation of intrapulmonary shunt fraction.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1212877     DOI: 10.1097/00003246-197509000-00001

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  5 in total

Review 1.  European Society of Intensive Care Medicine. Expert panel: the use of the pulmonary artery catheter.

Authors: 
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

2.  Effect of balloon inflation volume on pulmonary artery occlusion pressure in patients with and without pulmonary hypertension.

Authors:  Adriano R Tonelli; Kamal K Mubarak; Ning Li; Robin Carrie; Hassan Alnuaimat
Journal:  Chest       Date:  2010-07-01       Impact factor: 9.410

3.  Mixed venous oxygen content and its meaning.

Authors:  R Hainsworth
Journal:  Intensive Care Med       Date:  1981       Impact factor: 17.440

4.  Mixed venous blood gas sampling is not influenced by the speed of withdrawal in cardiac surgery patients.

Authors:  Emmanuel Sirdar; Jean-Gilles Guimond; Isabelle Coiteux; Sylvain Bélisle; Denis Babin; Marie-Claude Guertin; André Denault
Journal:  Intensive Care Med       Date:  2004-07-28       Impact factor: 17.440

5.  Accuracy assessment for three fiberoptic pulmonary artery catheters for SvO2 monitoring.

Authors:  A Armaganidis; J F Dhainaut; J L Billard; K Klouche; J P Mira; F Brunet; A T Dinh-Xuan; J Dall'Ava-Santucci
Journal:  Intensive Care Med       Date:  1994-08       Impact factor: 17.440

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.