A dosimetric comparison of various multileaf collimators.

M Saiful Huq1, Indra J Das, Todd Steinberg, James M Galvin.   

Abstract

The dosimetric characteristics of three multileaf collimator (MLC) systems (Elekta, Siemens and Varian) having 10 mm leaf width are compared. A 6 MV photon beam was used from each unit for measurements. Film dosimetry was performed for the measurements and the analysis techniques were exactly duplicated in each system. Two of the collimators have rounded leaf ends (Elekta and Varian) and the third (Siemens) has a flat end that follows beam divergence. A scanning densitometer (Wellhöfer with 0.45 mm spot and 0.5 mm step size) was used for film analysis. The dosimetric characteristics studied include: penumbra width (80-20%) as a function of position of the leaf end in the field, inter- and intra-leaf radiation leakage, dose distribution of the tongue and groove, and isodose curves for stepped leaves forming 45 degrees angle beam edge. Results show that MLC designs with divergent and non-divergent leaves produce penumbra (80-20%) widths that are within 2.0 mm of each other. However, the distance of the collimator from the x-ray target plays an important role, and the smallest penumbra width was noted for the Varian MLC despite its rounded leaf-end design. Compared to the other systems, this collimator is positioned about 15 cm closer to the patient which affects the skin dose. The MLC with flat leaf end, although closer to the target, showed slightly poorer penumbra width. Inter-leaf leakage through the leaves is 1.3% for two of the collimators (Elekta and Varian) with the backup jaws and is nearly 1% for the third system (Siemens). The Siemens MLC produces reduced tongue-and-groove effect compared to the other two collimators (Elekta and Varian). The isodose undulation for a stepped edge is found to be significant for the collimator closest to the patient (Varian) and does not depend on the leaf-end shape. There is no perfect MLC system that can be recommended, rather each one has unique advantages and disadvantages that should be weighed with comfort, ease and cost effectiveness for clinical use.

Entities:  

Mesh:

Year:  2002        PMID: 12118609     DOI: 10.1088/0031-9155/47/12/401

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery.

Authors:  J A Tanyi; C M Kato; Y Chen; Z Chen; M Fuss
Journal:  Br J Radiol       Date:  2010-10-05       Impact factor: 3.039

2.  A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation.

Authors:  P Rowshanfarzad; H L Riis; S J Zimmermann; M A Ebert
Journal:  Br J Radiol       Date:  2015-04-23       Impact factor: 3.039

3.  Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4.

Authors:  Hiroyuki Okamoto; Yukio Fujita; Kyoko Sakama; Hidetoshi Saitoh; Tatsuaki Kanai; Jun Itami; Toshiyuki Kohno
Journal:  Radiol Phys Technol       Date:  2014-02-08

4.  Calculating and estimating second cancer risk from breast radiotherapy using Monte Carlo code with internal body scatter for each out-of-field organ.

Authors:  Takeshi Takata; Kenshiro Shiraishi; Shinobu Kumagai; Norikazu Arai; Takenori Kobayashi; Hiroshi Oba; Takahide Okamoto; Jun'ichi Kotoku
Journal:  J Appl Clin Med Phys       Date:  2020-10-30       Impact factor: 2.102

5.  Immediate reconstruction with an expander/implant following ablatio mammae because of breast cancer : side effects and cosmetic results after adjuvant chest wall radiotherapy.

Authors:  Marc D Piroth; Daniela M Piroth; Michael Pinkawa; Seth G Woodruff; Richard Holy; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2009-10-06       Impact factor: 3.621

6.  Stereotactic body radiosurgery for spinal metastatic disease: an evidence-based review.

Authors:  William A Hall; Liza J Stapleford; Costas G Hadjipanayis; Walter J Curran; Ian Crocker; Hui-Kuo G Shu
Journal:  Int J Surg Oncol       Date:  2011-07-10

7.  Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

Authors:  Dayananda Shamurailatpam Sharma; Prabhakar M Dongre; Vaibav Mhatre; Malhotra Heigrujam
Journal:  J Appl Clin Med Phys       Date:  2011-04-14       Impact factor: 2.102

8.  Suggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems.

Authors:  Sanaz Hariri; Majid Shahriari
Journal:  J Appl Clin Med Phys       Date:  2010-06-15       Impact factor: 2.102

9.  Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions.

Authors:  Q Jackie Wu; Zhiheng Wang; John P Kirkpatrick; Zheng Chang; Jeffrey J Meyer; Mei Lu; Calvin Huntzinger; Fang-Fang Yin
Journal:  Radiat Oncol       Date:  2009-01-21       Impact factor: 3.481

10.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.