Performance of isotropic light dosimetry probes based on scattering bulbs in turbid media.

J P A Marijnissen1, W M Star.   

Abstract

In a previous paper the calibration of an isotropic light detector in clear media was described and validated. However, in most applications the detector is used to measure light distribution in turbid (scattering) media, that is, in tissues or tissue equivalent optical phantoms. Despite its small diameter (typically 0.8 mm), inserting the detector in a turbid medium may perturb the light distribution and change the fluence rate at the point of measurement. In the present paper we estimate the error in the fluence rate measured by a detector in turbid media after calibration in a clear medium (air), using an optical phantom and detector bulbs of different optical properties. The experimental results are compared with calculations using the diffusion approximation to the transport equation in a spherical geometry. From measurements in optical phantoms and the results of the calculations it appears that introduction of the detector into a water-based turbid medium with refractive index, absorption- and scattering coefficients different from those of the detector bulb may require corrections to the detector response of up to 10-15%, in order to obtain the true fluence rate in that medium. The diffusion model is used to explore the detector response in a number of tissues of interest in photodynamic therapy, using tissue optical properties from the literature. Based on these model calculations it is estimated that in real tissues the fluence rate measured by the detector is up to 3% below the true value.

Entities:  

Mesh:

Year:  2002        PMID: 12118600     DOI: 10.1088/0031-9155/47/12/304

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  A method for determination of the absorption and scattering properties interstitially in turbid media.

Authors:  Andreea Dimofte; Jarod C Finlay; Timothy C Zhu
Journal:  Phys Med Biol       Date:  2005-05-05       Impact factor: 3.609

Review 2.  The role of photodynamic therapy (PDT) physics.

Authors:  Timothy C Zhu; Jarod C Finlay
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

3.  Light Dosimetry at Tissue Surfaces for Oblique Incident Circular Fields.

Authors:  Timothy C Zhu; Jarod C Finlay; Andreea Dimofte; Stephen M Hahn
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004

4.  Light Dosimetry at Tissue Surfaces for Small Circular Fields.

Authors:  Timothy C Zhu; Andreea Dimofte; Stephen M Hahn; Robert A Lustig
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2003-06-12

5.  Optical dosimetry probes to validate Monte Carlo and empirical-method-based NIR dose planning in the brain.

Authors:  Akshay Prabhu Verleker; Michael Shaffer; Qianqian Fang; Mi-Ran Choi; Susan Clare; Keith M Stantz
Journal:  Appl Opt       Date:  2016-12-01       Impact factor: 1.980

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.