Literature DB >> 27958483

Optical dosimetry probes to validate Monte Carlo and empirical-method-based NIR dose planning in the brain.

Akshay Prabhu Verleker, Michael Shaffer, Qianqian Fang, Mi-Ran Choi, Susan Clare, Keith M Stantz.   

Abstract

A three-dimensional photon dosimetry in tissues is critical in designing optical therapeutic protocols to trigger light-activated drug release. The objective of this study is to investigate the feasibility of a Monte Carlo-based optical therapy planning software by developing dosimetry tools to characterize and cross-validate the local photon fluence in brain tissue, as part of a long-term strategy to quantify the effects of photoactivated drug release in brain tumors. An existing GPU-based 3D Monte Carlo (MC) code was modified to simulate near-infrared photon transport with differing laser beam profiles within phantoms of skull bone (B), white matter (WM), and gray matter (GM). A novel titanium-based optical dosimetry probe with isotropic acceptance was used to validate the local photon fluence, and an empirical model of photon transport was developed to significantly decrease execution time for clinical application. Comparisons between the MC and the dosimetry probe measurements were on an average 11.27%, 13.25%, and 11.81% along the illumination beam axis, and 9.4%, 12.06%, 8.91% perpendicular to the beam axis for WM, GM, and B phantoms, respectively. For a heterogeneous head phantom, the measured % errors were 17.71% and 18.04% along and perpendicular to beam axis. The empirical algorithm was validated by probe measurements and matched the MC results (R<sup>2</sup>>0.99), with average % error of 10.1%, 45.2%, and 22.1% relative to probe measurements, and 22.6%, 35.8%, and 21.9% relative to the MC, for WM, GM, and B phantoms, respectively. The simulation time for the empirical model was 6 s versus 8 h for the GPU-based Monte Carlo for a head phantom simulation. These tools provide the capability to develop and optimize treatment plans for optimal release of pharmaceuticals in the treatment of cancer. Future work will test and validate these novel delivery and release mechanisms in vivo.

Entities:  

Mesh:

Year:  2016        PMID: 27958483      PMCID: PMC5483856          DOI: 10.1364/AO.55.009875

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  22 in total

1.  Performance of isotropic light dosimetry probes based on scattering bulbs in turbid media.

Authors:  J P A Marijnissen; W M Star
Journal:  Phys Med Biol       Date:  2002-06-21       Impact factor: 3.609

2.  Accuracies of the diffusion approximation and its similarity relations for laser irradiated biological media.

Authors:  G Yoon; S A Prahl; A J Welch
Journal:  Appl Opt       Date:  1989-06-15       Impact factor: 1.980

3.  In vivo measurement of the optical interaction coefficients of human tumours at 630 nm.

Authors:  I Driver; C P Lowdell; D V Ash
Journal:  Phys Med Biol       Date:  1991-06       Impact factor: 3.609

4.  Calibration of isotropic light dosimetry probes based on scattering bulbs in clear media.

Authors:  J P Marijnissen; W M Star
Journal:  Phys Med Biol       Date:  1996-07       Impact factor: 3.609

Review 5.  Light dosimetry in vivo.

Authors:  W M Star
Journal:  Phys Med Biol       Date:  1997-05       Impact factor: 3.609

6.  Ex vivo light dosimetry and Monte Carlo simulations for endobronchial photodynamic therapy.

Authors:  L H Murrer; J P Marijnissen; W M Star
Journal:  Phys Med Biol       Date:  1995-11       Impact factor: 3.609

7.  Measurement of the optical properties of the skull in the wavelength range 650-950 nm.

Authors:  M Firbank; M Hiraoka; M Essenpreis; D T Delpy
Journal:  Phys Med Biol       Date:  1993-04       Impact factor: 3.609

8.  Hybrid model of Monte Carlo simulation and diffusion theory for light reflectance by turbid media.

Authors:  L Wang; S L Jacques
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1993-08       Impact factor: 2.129

9.  Quantification of adult cerebral hemodynamics by near-infrared spectroscopy.

Authors:  C E Elwell; M Cope; A D Edwards; J S Wyatt; D T Delpy; E O Reynolds
Journal:  J Appl Physiol (1985)       Date:  1994-12

10.  Phantom measurements for light dosimetry using isotropic and small aperture detectors.

Authors:  J P Marynissen; W M Star
Journal:  Prog Clin Biol Res       Date:  1984
View more
  1 in total

1.  Optical dosimetry probes to validate Monte Carlo and empirical-method-based NIR dose planning in the brain: publisher's note.

Authors:  Akshay Prabhu Verleker; Michael Shaffer; Qianqian Fang; Mi-Ran Choi; Susan Clare; Keith M Stantz
Journal:  Appl Opt       Date:  2017-02-01       Impact factor: 1.980

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.